Recently, I have just updated little bit..
Add an accmulating graph, It can make me easy to read how much power has generated/used easily.
Around 50 yard in front of my house, there are some big trees.
I make some shadow on my house now.
Power gain is not even, and, drop power at end of day ~
actually, the shadow is not much horrible to reduce the power to the diffusion power level.
but, It is a problem with solar power generation.
I hate the trees, but, I can do nothing ~ because it is not belong to me.
When install a solar system, need to consider more carefully,
The top-left panel are shaded, just little bit, What will happen ? just guess ?
Yea, lost 1/2 energy. Technically, solar panel is not working like that..
(1) 20 cells are in a string, and
(2) 3 strings in a panel (that is why there are three by-pass diode)
If half of one cell is shadowing, the cell will generate much lower current and/or voltage drop.
those string will makes much weak power such as 10-20% (power base on the diffusion light)
The other two strings will generate the power normally, so, it will generate 100%.
100% * 2 strings * 2/3 = 66.7%
10% * 1 strings * 1/3 = 33.3%
so, finally, the power generation should be around 70%, BUT, Enphase inverter has a problem in MPPT.
They track the lower peak instead higher peak in this situation. and generate 3.3% * 3 = 10% intead 70%.
by the result, just 50% of power can be havested in this situation.
This kind of problem is happening with a full sun-light condition also. when three string show full power,
but, there are some cell mis-matching. it will generate 2-3% flatten peak points near highest power point.
Enphase inverter is detecting the lowest peak one, instead highest one also. and, it can reduce the power by 2-3% also.
You can observe the discontinual highest power peak when shutting by cloude. because, when shuttering, this inver can find the highest point, but by time, keep going down, and stay at the lowest-peak power again.
Due to the tracking problem, Enphase Micro-inverter can not havest 100% enery, if they fix it.
The power yeild can be increased 1-2% for the good sun-light condition, and by 5-30% for the shading condition.
THIS IS FAKE !!!! DO NOT BE FOOLED, IT IS REVERSED !!!
https://www.solarreviews.com/blog/pros-and-cons-of-string-inverter-vs-microinverter
If one cell has shaded completely, Panel voltage will drop 2/3 of normal voltage, will out-of-range of Enphase Inverter, and will not working. Even string/optimizer can handle it. BUT, Enphase MI can not handle it. Don't be fooled.
Top-right panel : 1/2 of one cell has shaded, that is why it can show 50%. if the cell has shaded completely, it will show 10%.
* Good Article to Understand Shading Model