Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.048 kW
07/28/2025 07:13 (1888 days) Production Consumption NET Usage
Now 0.399 kW 0.351 kW -0.048 kW
Today 0.205 kWh (0.028 kW) 5.337 kWh (0.736 kW) 5.132 kWh (0.708 kW)
  - This Week 12.009 kWh (9.224 kWh/day) 36.029 kWh (27.674 kWh/day) 24.020 kWh (18.450 kWh/day)
  - This Month 633.137 kWh (23.190 kWh/day) 1057.542 kWh (38.735 kWh/day) 424.405 kWh (15.545 kWh/day)
  - This Year 3.663 MWh (17.584 kWh/day) 4.185 MWh (20.090 kWh/day) 0.522 MWh (2.506 kWh/day)
Yesterday 11.804 kWh (0.492 kW) 30.692 kWh (1.279 kW) 18.888 kWh (0.787 kW)
Last 7 Days 156.424 kWh (22.347 kWh/day) 229.299 kWh (32.758 kWh/day) 72.875 kWh (10.411 kWh/day)
Last 30 Days 711.400 kWh (23.714 kWh/day) 1143.717 kWh (38.125 kWh/day) 432.317 kWh (14.411 kWh/day)
Last One Year 6.268 MWh (17.172 kWh/day) 6.737 MWh (18.458 kWh/day) 0.469 MWh (1.285 kWh/day)
Lifetime Since PTO 33.114 MWh (17.536 kW/day) 36.137 MWh (19.137 kW/day) 3.023 MWh (1.601 kW/day)
Lifetime Since Install 33.148 MWh 36.717 MWh 3.569 MWh
Voltage/Current 254.8 V / 1.6 A 254.9 V / 1.4 A 254.8 V / -0.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/17/2025 23:22 (14.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.320 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.866 1.047 9.943 0.000 kW
1.824 kWh
0.000 kW
10.945 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.283 1.778 0.999 9.345
03 - 202224****** IQ7+M [5] VCOP 0.000 0.291 1.842 1.037 9.670
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.868 1.046 9.840
05 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.768 0.985 8.884
06 - 202245****** IQ7+M [5] VC-- 0.000 0.288 1.824 1.017 9.583
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 1.821 1.002 9.219 0.000 kW
1.808 kWh
0.000 kW
9.041 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.756 1.004 9.121
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.777 1.012 9.189
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.825 1.015 9.296
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.862 1.023 9.434
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.278 1.546 0.874 9.115 0.000 kW
1.583 kWh
0.000 kW
6.333 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.280 1.547 0.881 9.139
14 - 202216****** IQ7+ [5] VCOP 0.000 0.273 1.618 0.935 9.527
15 - 202245****** IQ7+M [5] VCOP 0.000 0.270 1.622 0.934 9.533
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 1.30 V Voltage Charge 52.30 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.8 °C / 25.7 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-05-17 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.55 V Current/Power -6.30 A (-0.331 kW)
Remain Capacity/Energy 288.6 Ah (14.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 48.7 % State Of Health 98.9 %
Run Time 1d 21h 48m to empty Report Date 2025-05-17 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.