Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.530 kW
05/23/2026 12:11 (2187 days) Production Consumption NET Usage
Now 0.804 kW 0.274 kW -0.530 kW
Today 2.786 kWh (0.228 kW) 2.211 kWh (0.181 kW) -0.575 kWh (-0.047 kW)
  - This Week 158.158 kWh (24.298 kWh/day) 151.480 kWh (23.272 kWh/day) -6.678 kWh (-1.026 kWh/day)
  - This Month 559.974 kWh (24.878 kWh/day) 351.202 kWh (15.603 kWh/day) -208.772 kWh (-9.275 kWh/day)
  - This Year 2.513 MWh (17.634 kWh/day) 2.411 MWh (16.918 kWh/day) -0.102 MWh (-0.716 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 179.179 kWh (25.597 kWh/day) 157.211 kWh (22.459 kWh/day) -21.968 kWh (-3.138 kWh/day)
Last 30 Days (04/23/2026) 712.941 kWh (23.765 kWh/day) 419.818 kWh (13.994 kWh/day) -293.123 kWh (-9.771 kWh/day)
Last One Year 6.391 MWh (17.508 kWh/day) 7.786 MWh (21.331 kWh/day) 1.395 MWh (3.822 kWh/day)
Lifetime Since PTO 38.079 MWh (17.407 kW/day) 41.922 MWh (19.164 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.113 MWh 42.502 MWh 4.389 MWh
Voltage/Current 249.0 V / 3.2 A 248.9 V / 1.1 A 249.0 V / -2.1 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/30/2024 23:45 (8.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.191 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.215 1.047 0.425 4.267 0.000 kW
1.028 kWh
0.000 kW
6.171 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.205 0.998 0.405 4.080
03 - 202224****** IQ7+M [5] VCOP 0.000 0.211 1.042 0.418 4.220
04 - 202232****** IQ7+ [5] VCOP 0.000 0.211 1.055 0.418 4.245
05 - 202244****** IQ7+M [5] VCOP 0.000 0.206 1.007 0.406 4.094
06 - 202245****** IQ7+M [5] VCOP 0.000 0.209 1.021 0.419 4.202
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.274 1.099 0.386 4.497 0.000 kW
1.250 kWh
0.000 kW
6.252 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.282 1.246 0.470 4.942
09 - 202217****** IQ7+ [5] VCOP 0.000 0.282 1.340 0.470 5.212
10 - 202244****** IQ7+M [5] VCOP 0.000 0.274 1.323 0.473 5.185
11 - 202224****** IQ7+M [5] VCOP 0.000 0.278 1.243 0.462 4.968
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.083 0.367 0.255 2.046 0.000 kW
0.442 kWh
0.000 kW
1.768 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.093 0.443 0.279 2.299
14 - 202216****** IQ7+ [5] VCOP 0.000 0.097 0.483 0.317 2.567
15 - 202245****** IQ7+M [5] VCOP 0.000 0.095 0.475 0.319 2.528
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.005
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 0.83 V Voltage Charge 52.97 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 27.2 °C / 24.1 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-11-30 23:59
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.