Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.461 kW
12/26/2025 14:52 (2039 days) Production Consumption NET Usage
Now 0.124 kW 0.585 kW 0.461 kW
Today 5.222 kWh (0.351 kW) 7.429 kWh (0.499 kW) 2.207 kWh (0.148 kW)
  - This Week 49.350 kWh (8.781 kWh/day) 78.992 kWh (14.055 kWh/day) 29.642 kWh (5.274 kWh/day)
  - This Month 224.256 kWh (8.753 kWh/day) 502.273 kWh (19.605 kWh/day) 278.017 kWh (10.852 kWh/day)
  - This Year 6.093 MWh (16.944 kWh/day) 7.419 MWh (20.629 kWh/day) 1.325 MWh (3.685 kWh/day)
Yesterday 7.034 kWh (0.293 kW) 15.848 kWh (0.661 kW) 8.814 kWh (0.367 kW)
Last 7 Days 59.917 kWh (8.560 kWh/day) 105.329 kWh (15.048 kWh/day) 45.412 kWh (6.488 kWh/day)
Last 30 Days 264.277 kWh (8.809 kWh/day) 620.513 kWh (20.684 kWh/day) 356.236 kWh (11.875 kWh/day)
Last One Year 6.142 MWh (16.828 kWh/day) 7.583 MWh (20.776 kWh/day) 1.441 MWh (3.948 kWh/day)
Lifetime Since PTO 35.544 MWh (17.426 kW/day) 39.371 MWh (19.303 kW/day) 3.827 MWh (1.876 kW/day)
Lifetime Since Install 35.578 MWh 39.951 MWh 4.373 MWh
Voltage/Current 248.7 V / 0.5 A 248.7 V / 2.4 A 248.7 V / 1.9 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/08/2024 23:48 (12.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.375 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.073 0.239 0.310 8.614 0.000 kW
0.230 kWh
0.000 kW
1.379 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.068 0.223 0.289 8.019
03 - 202224****** IQ7+M [5] VCOP 0.000 0.070 0.238 0.308 8.336
04 - 202232****** IQ7+ [5] VCOP 0.000 0.072 0.236 0.306 8.497
05 - 202244****** IQ7+M [5] VCOP 0.000 0.067 0.217 0.282 7.433
06 - 202245****** IQ7+M [5] VCOP 0.000 0.068 0.226 0.293 8.170
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.064 0.213 0.274 7.694 0.000 kW
0.214 kWh
0.000 kW
1.069 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.063 0.214 0.277 7.709
09 - 202217****** IQ7+ [5] VCOP 0.000 0.063 0.214 0.275 7.679
10 - 202244****** IQ7+M [5] VCOP 0.000 0.064 0.214 0.277 7.741
11 - 202224****** IQ7+M [5] VCOP 0.000 0.064 0.214 0.279 7.856
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.064 0.212 0.278 8.177 0.000 kW
0.232 kWh
0.000 kW
0.927 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.069 0.226 0.298 8.420
14 - 202216****** IQ7+ [5] VCOP 0.000 0.070 0.246 0.317 8.731
15 - 202245****** IQ7+M [5] VCOP 0.000 0.071 0.243 0.315 8.726
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.000 0.000 0.000 31.667
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 52.58 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 231.0 Ah (11.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 39.0 % State Of Health 98.9 %
Run Time 8d 0h 30m to empty Report Date 2024-08-08 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack