| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Exporting to grid by 0.585 kW | |||
|---|---|---|---|
| 05/23/2026 13:54 (2187 days) | Production | Consumption | NET Usage |
| Now | 0.380 kW | -0.205 kW | -0.585 kW |
| Today | 3.619 kWh (0.260 kW) | 3.395 kWh (0.244 kW) | -0.224 kWh (-0.016 kW) |
| - This Week | 158.991 kWh (24.163 kWh/day) | 152.664 kWh (23.201 kWh/day) | -6.327 kWh (-0.962 kWh/day) |
| - This Month | 560.807 kWh (24.837 kWh/day) | 352.386 kWh (15.606 kWh/day) | -208.421 kWh (-9.231 kWh/day) |
| - This Year | 2.514 MWh (17.631 kWh/day) | 2.412 MWh (16.918 kWh/day) | -0.102 MWh (-0.714 kWh/day) |
| Yesterday | 29.595 kWh (1.233 kW) | 5.105 kWh (0.213 kW) | -24.490 kWh (-1.020 kW) |
| Last 7 Days | 173.086 kWh (24.727 kWh/day) | 157.900 kWh (22.557 kWh/day) | -15.186 kWh (-2.169 kWh/day) |
| Last 30 Days (04/23/2026) | 707.346 kWh (23.578 kWh/day) | 420.465 kWh (14.015 kWh/day) | -286.881 kWh (-9.563 kWh/day) |
| Last One Year | 6.389 MWh (17.505 kWh/day) | 7.786 MWh (21.332 kWh/day) | 1.397 MWh (3.827 kWh/day) |
| Lifetime Since PTO | 38.080 MWh (17.407 kW/day) | 41.923 MWh (19.164 kW/day) | 3.843 MWh (1.757 kW/day) |
| Lifetime Since Install | 38.113 MWh | 42.503 MWh | 4.389 MWh |
| Voltage/Current | 248.8 V / 1.5 A | 248.9 V / -0.8 A | 248.9 V / -2.4 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 01/12/2025 23:54 (9.2 hours) | Number of Devices | 17 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 12.556 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.224 | 0.942 | 0.234 | 5.205 | 0.000 kW 0.915 kWh |
0.000 kW 5.490 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.212 | 0.892 | 0.227 | 4.970 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.218 | 0.924 | 0.238 | 5.233 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.215 | 0.926 | 0.246 | 5.276 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.210 | 0.893 | 0.265 | 5.063 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.213 | 0.913 | 0.269 | 5.112 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.277 | 0.916 | 0.361 | 5.807 | 0.000 kW 1.050 kWh |
0.000 kW 5.249 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.274 | 1.056 | 0.366 | 6.412 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.279 | 1.133 | 0.369 | 6.809 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.274 | 1.110 | 0.378 | 6.732 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.280 | 1.035 | 0.353 | 6.379 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.092 | 0.398 | 0.121 | 1.935 | 0.000 kW 0.454 kWh |
0.000 kW 1.817 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.103 | 0.463 | 0.130 | 2.276 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.106 | 0.482 | 0.126 | 2.347 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.105 | 0.474 | 0.139 | 2.327 | |||
| wind | 16 - 202320****** | IQ7XS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
||||||||||
| Charger History | |||||
|---|---|---|---|---|---|
| Voltage PV | 1.67 V | Voltage Charge | 53.12 V | Current/Power | 0.00 A / 0.000 kW |
| Int/Ext Temp | 24.6 °C / 22.3 °C | Flags | 00/00/00 | Energy Today | 5.573 kWh @ 2025-01-12 23:55 |
|
|||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.29 V | Current/Power | -1.20 A (-63 W) |
| Remain Capacity/Energy | 387.0 Ah (19.8 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 65.3 % | State Of Health | 98.9 % |
| Run Time | 13d 10h 29m to empty | Report Date | 2025-01-12 23:59 |
|
|||
| Voltage | 53.29 V | Cell (MIN/MAX) | 3.308 V / 3.336 V (0.028 V) |
|---|---|---|---|
| Current/Power | -0.43 A (-22 W) | Runtime | 12d 12h 0m to empty |
| Remain Capacity/Energy | 129.0 Ah (6.6 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
| State Of Charge | 65.3 % | State Of Health | 98.8 % |
| Temperature | 16.5 °C | Cycle | 178 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-01-12 23:59 |
| Voltage | 53.28 V | Cell (MIN/MAX) | 3.328 V / 3.331 V (0.003 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.0 Ah (5.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.5 % |
| Temperature | 19.4 °C | Cycle | 111 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-01-12 23:59 |
| Voltage | 53.32 V | Cell (MIN/MAX) | 3.331 V / 3.332 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.0 Ah (5.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.5 % |
| Temperature | 18.1 °C | Cycle | 115 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-01-12 23:59 |
| Voltage | 53.28 V | Cell (MIN/MAX) | 3.329 V / 3.331 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.0 Ah (5.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.5 % |
| Temperature | 18.3 °C | Cycle | 117 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-01-12 23:59 |
| Voltage | 53.28 V | Cell (MIN/MAX) | 3.328 V / 3.331 V (0.003 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 98.7 Ah (5.1 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.2 % |
| Temperature | 18.9 °C | Cycle | 116 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-01-12 23:59 |