Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.283 kW
05/23/2026 20:46 (2187 days) Production Consumption NET Usage
Now 0.000 kW 0.283 kW 0.283 kW
Today 4.807 kWh (0.231 kW) 6.387 kWh (0.307 kW) 1.580 kWh (0.076 kW)
  - This Week 160.179 kWh (23.327 kWh/day) 155.656 kWh (22.668 kWh/day) -4.523 kWh (-0.659 kWh/day)
  - This Month 561.995 kWh (24.578 kWh/day) 355.378 kWh (15.542 kWh/day) -206.617 kWh (-9.036 kWh/day)
  - This Year 2.515 MWh (17.604 kWh/day) 2.415 MWh (16.905 kWh/day) -0.100 MWh (-0.700 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 160.179 kWh (22.883 kWh/day) 157.399 kWh (22.486 kWh/day) -2.780 kWh (-0.397 kWh/day)
Last 30 Days (04/23/2026) 698.958 kWh (23.299 kWh/day) 421.057 kWh (14.035 kWh/day) -277.901 kWh (-9.263 kWh/day)
Last One Year 6.381 MWh (17.483 kWh/day) 7.784 MWh (21.326 kWh/day) 1.403 MWh (3.843 kWh/day)
Lifetime Since PTO 38.081 MWh (17.405 kW/day) 41.926 MWh (19.163 kW/day) 3.845 MWh (1.757 kW/day)
Lifetime Since Install 38.115 MWh 42.506 MWh 4.391 MWh
Voltage/Current 248.4 V / 0.0 A 248.2 V / 1.1 A 248.3 V / 1.1 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/26/2025 23:29 (11.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.206 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.225 0.826 0.672 5.427 0.000 kW
0.860 kWh
0.000 kW
5.160 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.234 0.829 0.697 5.009
03 - 202224****** IQ7+M [0] ---- 0.000 0.253 0.820 0.735 4.398
04 - 202232****** IQ7+ [0] ---- 0.000 0.282 0.903 0.839 7.252
05 - 202244****** IQ7+M [0] ---- 0.000 0.276 0.913 1.743 8.290
06 - 202245****** IQ7+M [0] ---- 0.000 0.243 0.869 0.645 6.379
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.286 0.957 1.924 9.481 0.000 kW
0.941 kWh
0.000 kW
4.705 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.290 0.961 1.272 9.436
09 - 202217****** IQ7+ [0] ---- 0.000 0.288 0.955 1.836 10.270
10 - 202244****** IQ7+M [0] ---- 0.000 0.229 0.861 0.684 4.462
11 - 202224****** IQ7+M [0] ---- 0.000 0.291 0.972 2.000 10.543
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.225 0.775 1.374 7.646 0.000 kW
0.835 kWh
0.000 kW
3.341 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.230 0.838 1.503 7.911
14 - 202216****** IQ7+ [0] ---- 0.000 0.234 0.867 1.550 8.183
15 - 202245****** IQ7+M [0] ---- 0.000 0.230 0.862 1.531 8.104
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 0.39 V Voltage Charge 52.14 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.6 °C / 25.1 °C Flags 00/00/00 Energy Today 5.509 kWh @ 2025-03-26 23:57
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.