Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.755 kW
12/26/2025 18:22 (2039 days) Production Consumption NET Usage
Now 0.000 kW 0.755 kW 0.755 kW
Today 5.294 kWh (0.288 kW) 10.154 kWh (0.552 kW) 4.860 kWh (0.264 kW)
  - This Week 49.422 kWh (8.571 kWh/day) 81.717 kWh (14.172 kWh/day) 32.295 kWh (5.601 kWh/day)
  - This Month 224.328 kWh (8.706 kWh/day) 504.998 kWh (19.599 kWh/day) 280.670 kWh (10.893 kWh/day)
  - This Year 6.093 MWh (16.937 kWh/day) 7.421 MWh (20.628 kWh/day) 1.328 MWh (3.691 kWh/day)
Yesterday 7.034 kWh (0.293 kW) 15.848 kWh (0.661 kW) 8.814 kWh (0.367 kW)
Last 7 Days 59.917 kWh (8.560 kWh/day) 105.329 kWh (15.048 kWh/day) 45.412 kWh (6.488 kWh/day)
Last 30 Days 264.277 kWh (8.809 kWh/day) 620.513 kWh (20.684 kWh/day) 356.236 kWh (11.875 kWh/day)
Last One Year 6.142 MWh (16.828 kWh/day) 7.583 MWh (20.776 kWh/day) 1.441 MWh (3.948 kWh/day)
Lifetime Since PTO 35.544 MWh (17.425 kW/day) 39.374 MWh (19.303 kW/day) 3.830 MWh (1.878 kW/day)
Lifetime Since Install 35.578 MWh 39.954 MWh 4.376 MWh
Voltage/Current 250.0 V / 0.0 A 250.0 V / 3.0 A 250.0 V / 3.0 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/23/2024 23:46 (8.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.747 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.215 0.766 0.176 4.590 0.000 kW
0.753 kWh
0.000 kW
4.520 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.206 0.730 0.165 4.385
03 - 202224****** IQ7+M [0] ---- 0.000 0.211 0.762 0.173 4.517
04 - 202232****** IQ7+ [0] ---- 0.000 0.212 0.766 0.169 4.506
05 - 202244****** IQ7+M [0] ---- 0.000 0.208 0.735 0.158 4.418
06 - 202245****** IQ7+M [0] ---- 0.000 0.208 0.760 0.172 4.506
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.279 0.799 0.172 4.646 0.000 kW
0.905 kWh
0.000 kW
4.525 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.277 0.906 0.166 5.140
09 - 202217****** IQ7+ [0] ---- 0.000 0.281 0.953 0.169 5.534
10 - 202244****** IQ7+M [0] ---- 0.000 0.279 0.946 0.170 5.447
11 - 202224****** IQ7+M [0] ---- 0.000 0.284 0.920 0.154 5.159
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.129 0.388 0.148 2.272 0.000 kW
0.424 kWh
0.000 kW
1.697 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.128 0.419 0.161 2.574
14 - 202216****** IQ7+ [0] ---- 0.000 0.132 0.459 0.205 2.812
15 - 202245****** IQ7+M [0] ---- 0.000 0.122 0.431 0.192 2.752
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.003 kWh
0.000 kW
0.006 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.199 0.006 0.000 0.005
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 108.67 V (0.61 A) Voltage Charge 53.21 V Current/Power 1.18 A / 0.063 kW
Int/Ext Temp 38.7 °C / 25.7 °C Flags 00/00/0D Energy Today 3.645 kWh @ 2024-11-23 14:35
voltage in/out power and energy internal/external temperature