Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.228 kW
05/23/2026 15:09 (2187 days) Production Consumption NET Usage
Now 0.174 kW -0.054 kW -0.228 kW
Today 4.075 kWh (0.269 kW) 3.371 kWh (0.222 kW) -0.704 kWh (-0.046 kW)
  - This Week 159.447 kWh (24.042 kWh/day) 152.640 kWh (23.015 kWh/day) -6.807 kWh (-1.026 kWh/day)
  - This Month 561.263 kWh (24.800 kWh/day) 352.362 kWh (15.570 kWh/day) -208.901 kWh (-9.231 kWh/day)
  - This Year 2.514 MWh (17.628 kWh/day) 2.412 MWh (16.911 kWh/day) -0.102 MWh (-0.717 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 168.643 kWh (24.092 kWh/day) 157.644 kWh (22.521 kWh/day) -10.999 kWh (-1.571 kWh/day)
Last 30 Days (04/23/2026) 703.797 kWh (23.460 kWh/day) 419.947 kWh (13.998 kWh/day) -283.850 kWh (-9.462 kWh/day)
Last One Year 6.387 MWh (17.499 kWh/day) 7.786 MWh (21.331 kWh/day) 1.399 MWh (3.832 kWh/day)
Lifetime Since PTO 38.080 MWh (17.407 kW/day) 41.923 MWh (19.164 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.114 MWh 42.503 MWh 4.389 MWh
Voltage/Current 249.0 V / 0.7 A 249.0 V / -0.2 A 249.0 V / -0.9 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/27/2025 23:08 (13.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.748 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.287 1.538 0.686 11.526 0.000 kW
1.503 kWh
0.000 kW
9.021 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.481 0.652 10.918
03 - 202224****** IQ7+M [5] VCOP 0.000 0.289 1.522 0.679 11.349
04 - 202232****** IQ7+ [5] VCOP 0.000 0.293 1.530 0.680 11.526
05 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.441 0.638 10.510
06 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.510 0.665 11.078
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.285 1.469 0.639 10.969 0.000 kW
1.447 kWh
0.000 kW
7.235 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.286 1.391 0.631 11.022
09 - 202217****** IQ7+ [5] VCOP 0.000 0.287 1.403 0.634 11.003
10 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.472 0.650 11.122
11 - 202224****** IQ7+M [5] VCOP 0.000 0.287 1.501 0.654 11.323
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.286 1.345 0.597 9.940 0.000 kW
1.373 kWh
0.000 kW
5.492 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.287 1.354 0.616 10.081
14 - 202216****** IQ7+ [5] VCOP 0.000 0.283 1.396 0.644 10.404
15 - 202245****** IQ7+M [5] VCOP 0.000 0.290 1.396 0.644 10.409
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 0.59 V Voltage Charge 52.26 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 29.4 °C / 26.0 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-04-27 23:58
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.