Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.358 kW
05/23/2026 16:44 (2187 days) Production Consumption NET Usage
Now 0.332 kW -0.026 kW -0.358 kW
Today 4.446 kWh (0.265 kW) 3.956 kWh (0.236 kW) -0.490 kWh (-0.029 kW)
  - This Week 159.818 kWh (23.860 kWh/day) 153.225 kWh (22.876 kWh/day) -6.593 kWh (-0.984 kWh/day)
  - This Month 561.634 kWh (24.744 kWh/day) 352.947 kWh (15.550 kWh/day) -208.687 kWh (-9.194 kWh/day)
  - This Year 2.515 MWh (17.622 kWh/day) 2.413 MWh (16.907 kWh/day) -0.102 MWh (-0.715 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 163.719 kWh (23.388 kWh/day) 157.886 kWh (22.555 kWh/day) -5.833 kWh (-0.833 kWh/day)
Last 30 Days (04/23/2026) 700.691 kWh (23.356 kWh/day) 419.762 kWh (13.992 kWh/day) -280.929 kWh (-9.364 kWh/day)
Last One Year 6.383 MWh (17.489 kWh/day) 7.786 MWh (21.331 kWh/day) 1.402 MWh (3.842 kWh/day)
Lifetime Since PTO 38.080 MWh (17.407 kW/day) 41.923 MWh (19.163 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.114 MWh 42.503 MWh 4.389 MWh
Voltage/Current 248.6 V / 1.3 A 248.5 V / -0.1 A 248.5 V / -1.4 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/01/2025 23:04 (13.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.901 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.286 2.095 2.351 12.636 0.000 kW
2.011 kWh
0.000 kW
12.065 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.282 1.963 2.208 11.932
03 - 202224****** IQ7+M [5] VCOP 0.000 0.292 2.046 2.285 12.393
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 2.102 2.330 12.629
05 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.856 2.085 11.380
06 - 202245****** IQ7+M [5] VCOP 0.000 0.285 2.003 2.244 12.103
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.293 1.990 2.223 11.974 0.000 kW
2.004 kWh
0.000 kW
10.020 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.982 2.166 11.834
09 - 202217****** IQ7+ [5] VCOP 0.000 0.293 1.984 2.176 11.856
10 - 202244****** IQ7+M [5] VCOP 0.000 0.294 2.010 2.234 12.089
11 - 202224****** IQ7+M [5] VCOP 0.000 0.294 2.055 2.288 12.329
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.266 1.913 1.926 11.096 0.000 kW
1.954 kWh
0.000 kW
7.816 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.277 1.907 1.896 11.137
14 - 202216****** IQ7+ [5] VCOP 0.000 0.279 1.996 1.979 11.540
15 - 202245****** IQ7+M [5] VCOP 0.000 0.280 2.000 1.973 11.554
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 1.82 V Voltage Charge 52.76 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 27.9 °C / 24.9 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-05-01 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.03 V Current/Power -13.37 A (-0.709 kW)
Remain Capacity/Energy 370.9 Ah (19.0 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 62.5 % State Of Health 98.9 %
Run Time 1d 3h 44m to empty Report Date 2025-05-01 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.