Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.247 kW
05/23/2026 20:46 (2187 days) Production Consumption NET Usage
Now 0.000 kW 0.247 kW 0.247 kW
Today 4.807 kWh (0.231 kW) 6.385 kWh (0.307 kW) 1.578 kWh (0.076 kW)
  - This Week 160.179 kWh (23.328 kWh/day) 155.654 kWh (22.669 kWh/day) -4.525 kWh (-0.659 kWh/day)
  - This Month 561.995 kWh (24.578 kWh/day) 355.376 kWh (15.542 kWh/day) -206.619 kWh (-9.036 kWh/day)
  - This Year 2.515 MWh (17.604 kWh/day) 2.415 MWh (16.905 kWh/day) -0.100 MWh (-0.700 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 160.179 kWh (22.883 kWh/day) 157.397 kWh (22.485 kWh/day) -2.782 kWh (-0.397 kWh/day)
Last 30 Days (04/23/2026) 698.958 kWh (23.299 kWh/day) 421.054 kWh (14.035 kWh/day) -277.904 kWh (-9.263 kWh/day)
Last One Year 6.381 MWh (17.483 kWh/day) 7.784 MWh (21.326 kWh/day) 1.403 MWh (3.843 kWh/day)
Lifetime Since PTO 38.081 MWh (17.405 kW/day) 41.926 MWh (19.163 kW/day) 3.845 MWh (1.757 kW/day)
Lifetime Since Install 38.115 MWh 42.506 MWh 4.391 MWh
Voltage/Current 248.4 V / 0.0 A 248.2 V / 1.0 A 248.3 V / 1.0 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/30/2025 23:20 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.878 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.292 1.591 0.887 9.008 0.000 kW
1.568 kWh
0.000 kW
9.406 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.289 1.542 0.846 8.490
03 - 202224****** IQ7+M [0] ---- 0.000 0.292 1.576 0.876 8.639
04 - 202232****** IQ7+ [0] ---- 0.000 0.292 1.590 0.877 8.744
05 - 202244****** IQ7+M [0] ---- 0.000 0.292 1.539 0.831 7.913
06 - 202245****** IQ7+M [0] ---- 0.000 0.291 1.568 0.872 8.738
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.290 1.534 0.835 8.199 0.000 kW
1.534 kWh
0.000 kW
7.671 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.289 1.526 0.785 7.995
09 - 202217****** IQ7+ [0] ---- 0.000 0.289 1.536 0.822 8.123
10 - 202244****** IQ7+M [0] ---- 0.000 0.290 1.535 0.839 8.244
11 - 202224****** IQ7+M [0] ---- 0.000 0.291 1.540 0.829 8.236
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.271 1.387 0.759 8.832 0.000 kW
1.450 kWh
0.000 kW
5.801 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.277 1.422 0.787 8.950
14 - 202216****** IQ7+ [0] ---- 0.000 0.279 1.489 0.861 9.434
15 - 202245****** IQ7+M [0] ---- 0.000 0.281 1.502 0.865 9.459
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 1.57 V Voltage Charge 52.53 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.0 °C / 23.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-05-30 23:57
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.