Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 4.719 kW
05/23/2026 19:48 (2187 days) Production Consumption NET Usage
Now 0.000 kW 4.719 kW 4.719 kW
Today 4.807 kWh (0.243 kW) 5.182 kWh (0.261 kW) 0.375 kWh (0.019 kW)
  - This Week 160.179 kWh (23.466 kWh/day) 154.451 kWh (22.627 kWh/day) -5.728 kWh (-0.839 kWh/day)
  - This Month 561.995 kWh (24.621 kWh/day) 354.173 kWh (15.517 kWh/day) -207.822 kWh (-9.105 kWh/day)
  - This Year 2.515 MWh (17.609 kWh/day) 2.414 MWh (16.901 kWh/day) -0.101 MWh (-0.708 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 160.179 kWh (22.883 kWh/day) 156.582 kWh (22.369 kWh/day) -3.597 kWh (-0.514 kWh/day)
Last 30 Days (04/23/2026) 698.958 kWh (23.299 kWh/day) 419.792 kWh (13.993 kWh/day) -279.166 kWh (-9.306 kWh/day)
Last One Year 6.381 MWh (17.483 kWh/day) 7.785 MWh (21.327 kWh/day) 1.403 MWh (3.844 kWh/day)
Lifetime Since PTO 38.081 MWh (17.406 kW/day) 41.925 MWh (19.163 kW/day) 3.844 MWh (1.757 kW/day)
Lifetime Since Install 38.115 MWh 42.505 MWh 4.390 MWh
Voltage/Current 246.1 V / 0.0 A 246.0 V / 19.2 A 246.1 V / 19.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/04/2025 23:21 (15.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.959 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.280 2.228 2.245 10.002 0.000 kW
2.095 kWh
0.000 kW
12.572 kWh
02 - 202244****** IQ7+M [5] VC-- 0.000 0.267 2.114 2.075 9.457
03 - 202224****** IQ7+M [5] VC-- 0.000 0.277 1.796 2.109 9.693
04 - 202232****** IQ7+ [5] VC-- 0.000 0.284 2.226 2.170 9.789
05 - 202244****** IQ7+M [5] VC-- 0.000 0.269 2.035 1.873 9.022
06 - 202245****** IQ7+M [5] VC-- 0.000 0.274 2.173 2.149 9.698
front 07 - 202206****** IQ7+ [5] VC-- 0.000 0.274 2.082 2.004 9.156 0.000 kW
2.070 kWh
0.000 kW
10.349 kWh
08 - 202245****** IQ7+M [5] VC-- 0.000 0.277 1.999 1.984 9.036
09 - 202217****** IQ7+ [5] VC-- 0.000 0.276 2.024 1.994 9.130
10 - 202244****** IQ7+M [5] VC-- 0.000 0.274 2.098 2.006 9.216
11 - 202224****** IQ7+M [5] VC-- 0.000 0.280 2.147 2.040 9.281
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.242 1.967 2.201 9.549 0.000 kW
2.010 kWh
0.000 kW
8.038 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.248 1.956 2.213 9.729
14 - 202216****** IQ7+ [5] VCOP 0.000 0.250 2.045 2.272 10.110
15 - 202245****** IQ7+M [5] VC-- 0.000 0.252 2.070 2.271 10.126
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 0.90 V Voltage Charge 52.88 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.6 °C / 25.5 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-06-04 23:56
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.13 V Current/Power -6.36 A (-0.338 kW)
Remain Capacity/Energy 505.7 Ah (25.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 85.3 % State Of Health 98.9 %
Run Time 3d 7h 30m to empty Report Date 2025-06-04 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.