Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.813 kW
07/27/2025 00:54 (1887 days) Production Consumption NET Usage
Now 0.000 kW 0.813 kW 0.813 kW
Today 0.000 kWh (0.000 kW) 0.805 kWh (0.867 kW) 0.805 kWh (0.867 kW)
  - This Week 0.000 kWh 0.805 kWh 0.805 kWh
  - This Month 621.128 kWh (23.854 kWh/day) 1022.318 kWh (39.262 kWh/day) 401.190 kWh (15.407 kWh/day)
  - This Year 3.651 MWh (17.634 kWh/day) 4.150 MWh (20.042 kWh/day) 0.499 MWh (2.409 kWh/day)
Yesterday 26.728 kWh (1.113 kW) 39.650 kWh (1.651 kW) 12.922 kWh (0.538 kW)
Last 7 Days 169.271 kWh (24.185 kWh/day) 287.611 kWh (41.092 kWh/day) 118.340 kWh (16.908 kWh/day)
Last 30 Days 711.500 kWh (23.717 kWh/day) 1160.435 kWh (38.682 kWh/day) 448.935 kWh (14.965 kWh/day)
Last One Year 6.285 MWh (17.220 kWh/day) 6.722 MWh (18.417 kWh/day) 0.437 MWh (1.197 kWh/day)
Lifetime Since PTO 33.102 MWh (17.542 kW/day) 36.102 MWh (19.131 kW/day) 3.000 MWh (1.590 kW/day)
Lifetime Since Install 33.136 MWh 36.682 MWh 3.546 MWh
Voltage/Current 257.1 V / 0.0 A 256.9 V / 3.2 A 257.0 V / 3.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/10/2024 12:12 (5.0 hours) Number of Devices 16 set
Current Power 3.359 kW (0.210 kW/panel) Today Energy 7.790 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.240 0.240 0.568 1.530 9.283 0.235 kW
0.543 kWh
1.409 kW
3.260 kWh
02 - 202244****** IQ7+M [0] V--- 0.230 0.229 0.537 1.454 8.836
03 - 202224****** IQ7+M [0] V--- 0.236 0.235 0.554 1.501 9.129
04 - 202232****** IQ7+ [0] ---- 0.237 0.237 0.553 1.500 9.180
05 - 202244****** IQ7+M [0] ---- 0.231 0.231 0.519 1.448 8.725
06 - 202245****** IQ7+M [0] ---- 0.235 0.234 0.530 1.475 8.893
front 07 - 202206****** IQ7+ [0] ---- 0.256 0.255 0.319 1.549 9.159 0.257 kW
0.472 kWh
1.283 kW
2.361 kWh
08 - 202245****** IQ7+M [0] ---- 0.257 0.257 0.465 1.683 9.926
09 - 202217****** IQ7+ [0] V--- 0.257 0.255 0.530 1.682 9.985
10 - 202244****** IQ7+M [0] ---- 0.254 0.253 0.526 1.696 10.026
11 - 202224****** IQ7+M [0] ---- 0.259 0.257 0.521 1.717 10.151
back 12 - 202211****** IQ7+ [0] ---- 0.161 0.162 0.523 0.899 5.957 0.167 kW
0.542 kWh
0.667 kW
2.169 kWh
13 - 202223****** IQ7+ [0] ---- 0.167 0.168 0.539 0.957 6.331
14 - 202216****** IQ7+ [0] ---- 0.170 0.171 0.555 0.996 6.602
15 - 202245****** IQ7+M [0] ---- 0.169 0.170 0.552 0.990 6.557
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 16.293 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 109.55 V (16.50 A) Voltage Charge 54.24 V Current/Power 31.66 A / 1.717 kW
Int/Ext Temp 38.1 °C / 38.4 °C Flags 00/04/0D Energy Today 3.987 kWh @ 2024-10-10 12:13
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.84 V Current/Power 30.15 A (1.623 kW)
Remain Capacity/Energy 487.9 Ah (25.0 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 82.3 % State Of Health 98.9 %
Run Time 3h 29m to full Report Date 2024-10-10 12:11
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.