Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.296 kW
12/27/2025 06:02 (2040 days) Production Consumption NET Usage
Now 0.000 kW 0.296 kW 0.296 kW
Today 0.000 kWh (0.000 kW) 2.159 kWh (0.357 kW) 2.159 kWh (0.357 kW)
  - This Week 49.422 kWh (7.905 kWh/day) 90.908 kWh (14.540 kWh/day) 41.486 kWh (6.636 kWh/day)
  - This Month 224.328 kWh (8.545 kWh/day) 514.189 kWh (19.587 kWh/day) 289.861 kWh (11.041 kWh/day)
  - This Year 6.093 MWh (16.914 kWh/day) 7.431 MWh (20.626 kWh/day) 1.337 MWh (3.712 kWh/day)
Yesterday 5.294 kWh (0.220 kW) 17.186 kWh (0.716 kW) 11.892 kWh (0.495 kW)
Last 7 Days 61.642 kWh (8.806 kWh/day) 105.764 kWh (15.109 kWh/day) 44.122 kWh (6.303 kWh/day)
Last 30 Days 266.605 kWh (8.887 kWh/day) 623.590 kWh (20.787 kWh/day) 356.985 kWh (11.900 kWh/day)
Last One Year 6.136 MWh (16.812 kWh/day) 7.577 MWh (20.759 kWh/day) 1.441 MWh (3.947 kWh/day)
Lifetime Since PTO 35.544 MWh (17.421 kW/day) 39.383 MWh (19.303 kW/day) 3.839 MWh (1.882 kW/day)
Lifetime Since Install 35.578 MWh 39.963 MWh 4.385 MWh
Voltage/Current 248.7 V / 0.0 A 248.9 V / 1.2 A 248.8 V / 1.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/11/2025 23:13 (8.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.381 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.114 0.448 1.033 6.439 0.000 kW
0.433 kWh
0.000 kW
2.595 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.111 0.420 0.988 6.228
03 - 202224****** IQ7+M [0] ---- 0.000 0.114 0.443 1.029 6.517
04 - 202232****** IQ7+ [0] ---- 0.000 0.116 0.445 1.035 6.919
05 - 202244****** IQ7+M [0] ---- 0.000 0.106 0.414 0.965 6.655
06 - 202245****** IQ7+M [0] ---- 0.000 0.113 0.426 1.005 6.269
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.105 0.397 0.920 6.906 0.000 kW
0.402 kWh
0.000 kW
2.008 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.106 0.403 0.948 6.823
09 - 202217****** IQ7+ [0] ---- 0.000 0.106 0.400 0.947 6.822
10 - 202244****** IQ7+M [0] ---- 0.000 0.104 0.405 0.945 6.231
11 - 202224****** IQ7+M [0] ---- 0.000 0.107 0.404 0.951 7.151
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.108 0.420 0.993 6.385 0.000 kW
0.444 kWh
0.000 kW
1.778 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.112 0.442 1.027 6.528
14 - 202216****** IQ7+ [0] ---- 0.000 0.115 0.460 1.052 6.750
15 - 202245****** IQ7+M [0] ---- 0.000 0.115 0.456 1.053 6.736
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 1.97 V Voltage Charge 52.14 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 27.8 °C / 24.8 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-04-11 23:59
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.