Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.028 kW
05/23/2026 23:50 (2187 days) Production Consumption NET Usage
Now 0.000 kW 0.028 kW 0.028 kW
Today 4.807 kWh (0.202 kW) 7.168 kWh (0.301 kW) 2.361 kWh (0.099 kW)
  - This Week 160.179 kWh (22.902 kWh/day) 156.437 kWh (22.367 kWh/day) -3.742 kWh (-0.535 kWh/day)
  - This Month 561.995 kWh (24.441 kWh/day) 356.159 kWh (15.489 kWh/day) -205.836 kWh (-8.952 kWh/day)
  - This Year 2.515 MWh (17.588 kWh/day) 2.416 MWh (16.895 kWh/day) -0.099 MWh (-0.693 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 160.179 kWh (22.883 kWh/day) 156.479 kWh (22.354 kWh/day) -3.700 kWh (-0.529 kWh/day)
Last 30 Days (04/23/2026) 698.958 kWh (23.299 kWh/day) 420.764 kWh (14.025 kWh/day) -278.194 kWh (-9.273 kWh/day)
Last One Year 6.381 MWh (17.483 kWh/day) 7.782 MWh (21.320 kWh/day) 1.400 MWh (3.837 kWh/day)
Lifetime Since PTO 38.081 MWh (17.404 kW/day) 41.927 MWh (19.162 kW/day) 3.846 MWh (1.758 kW/day)
Lifetime Since Install 38.115 MWh 42.507 MWh 4.392 MWh
Voltage/Current 250.1 V / 0.0 A 250.2 V / 0.1 A 250.1 V / 0.1 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 09/12/2025 23:57 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 26.486 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.265 1.483 1.858 10.043 0.000 kW
1.448 kWh
0.000 kW
8.686 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.251 1.410 1.779 9.622
03 - 202224****** IQ7+M [0] ---- 0.000 0.259 1.462 1.853 10.029
04 - 202232****** IQ7+ [0] ---- 0.000 0.265 1.478 1.872 10.120
05 - 202244****** IQ7+M [0] ---- 0.000 0.252 1.406 1.717 9.376
06 - 202245****** IQ7+M [0] ---- 0.000 0.257 1.448 1.750 9.608
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.277 1.559 1.786 9.712 0.000 kW
1.576 kWh
0.000 kW
7.879 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.283 1.578 1.919 10.147
09 - 202217****** IQ7+ [0] ---- 0.000 0.280 1.569 1.885 10.009
10 - 202244****** IQ7+M [0] ---- 0.000 0.278 1.573 1.923 10.203
11 - 202224****** IQ7+M [0] ---- 0.000 0.284 1.599 1.951 10.332
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.207 1.054 1.472 8.223 0.000 kW
1.090 kWh
0.000 kW
4.362 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.212 1.070 1.478 8.378
14 - 202216****** IQ7+ [0] ---- 0.000 0.203 1.117 1.533 8.660
15 - 202245****** IQ7+M [0] ---- 0.000 0.216 1.121 1.534 8.673
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.780 kWh
0.230 kW
5.560 kWh
17 - 122214****** IQ7PD [0] ---- 0.230 0.230 5.560 5.504 38.506
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 0.69 V Voltage Charge 52.84 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.6 °C / 27.8 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-09-12 23:58
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.12 V Current/Power -6.23 A (-0.331 kW)
Remain Capacity/Energy 386.9 Ah (19.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 65.2 % State Of Health 98.9 %
Run Time 2d 14h 5m to empty Report Date 2025-09-12 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.