Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.071 kW
04/07/2026 01:15 (2141 days) Production Consumption NET Usage
Now 0.316 kW 0.387 kW 0.071 kW
Today 0.400 kWh (0.317 kW) 0.624 kWh (0.495 kW) 0.224 kWh (0.178 kW)
  - This Week 36.318 kWh (17.694 kWh/day) 25.325 kWh (12.338 kWh/day) -10.993 kWh (-5.356 kWh/day)
  - This Month 88.923 kWh (14.691 kWh/day) 86.384 kWh (14.272 kWh/day) -2.539 kWh (-0.419 kWh/day)
  - This Year 1.318 MWh (13.725 kWh/day) 1.652 MWh (17.196 kWh/day) 0.333 MWh (3.471 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 107.005 kWh (15.286 kWh/day) 101.143 kWh (14.449 kWh/day) -5.862 kWh (-0.837 kWh/day)
Last 30 Days (03/08/2026) 590.712 kWh (19.690 kWh/day) 445.201 kWh (14.840 kWh/day) -145.511 kWh (-4.850 kWh/day)
Last One Year 6.128 MWh (16.789 kWh/day) 7.831 MWh (21.455 kWh/day) 1.703 MWh (4.667 kWh/day)
Lifetime Since PTO 36.884 MWh (17.227 kW/day) 41.162 MWh (19.225 kW/day) 4.278 MWh (1.998 kW/day)
Lifetime Since Install 36.918 MWh 41.742 MWh 4.825 MWh
Voltage/Current 249.6 V / 1.3 A 249.5 V / 1.6 A 249.5 V / 0.3 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 08/03/2025 23:57 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 35.816 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.277 2.149 1.919 10.369 0.000 kW
2.046 kWh
0.000 kW
12.277 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.264 2.000 1.786 9.754
03 - 202224****** IQ7+M [0] ---- 0.000 0.274 2.074 1.852 10.050
04 - 202232****** IQ7+ [0] ---- 0.000 0.280 2.130 1.903 10.243
05 - 202244****** IQ7+M [0] ---- 0.000 0.266 1.873 1.654 9.168
06 - 202245****** IQ7+M [0] ---- 0.000 0.272 2.051 1.831 10.030
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.270 1.994 1.719 9.509 0.000 kW
2.000 kWh
0.000 kW
9.998 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.275 1.972 1.742 9.322
09 - 202217****** IQ7+ [0] ---- 0.000 0.272 1.973 1.734 9.408
10 - 202244****** IQ7+M [0] ---- 0.000 0.269 2.007 1.739 9.537
11 - 202224****** IQ7+M [0] ---- 0.000 0.276 2.052 1.762 9.628
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.239 1.974 1.899 9.733 0.000 kW
2.009 kWh
0.000 kW
8.034 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.245 1.964 1.932 9.848
14 - 202216****** IQ7+ [0] ---- 0.000 0.246 2.044 1.968 10.276
15 - 202245****** IQ7+M [0] ---- 0.000 0.247 2.052 1.978 10.332
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.753 kWh
0.230 kW
5.507 kWh
17 - 122214****** IQ7PD [0] ---- 0.230 0.230 5.507 5.497 8.840
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 0.71 V Voltage Charge 52.32 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 32.0 °C / 29.1 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-08-03 23:59
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.