Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.803 kW
04/06/2026 20:05 (2140 days) Production Consumption NET Usage
Now 0.316 kW 1.119 kW 0.803 kW
Today 30.221 kWh (1.503 kW) 5.886 kWh (0.293 kW) -24.335 kWh (-1.210 kW)
  - This Week 34.682 kWh (18.876 kWh/day) 25.491 kWh (13.874 kWh/day) -9.191 kWh (-5.002 kWh/day)
  - This Month 87.287 kWh (14.953 kWh/day) 86.550 kWh (14.827 kWh/day) -0.737 kWh (-0.126 kWh/day)
  - This Year 1.317 MWh (13.739 kWh/day) 1.652 MWh (17.236 kWh/day) 0.335 MWh (3.497 kWh/day)
Yesterday 4.461 kWh (0.186 kW) 19.605 kWh (0.817 kW) 15.144 kWh (0.631 kW)
Last 7 Days 105.369 kWh (15.053 kWh/day) 104.300 kWh (14.900 kWh/day) -1.069 kWh (-0.153 kWh/day)
Last 30 Days (03/07/2026) 589.076 kWh (19.636 kWh/day) 448.554 kWh (14.952 kWh/day) -140.522 kWh (-4.684 kWh/day)
Last One Year 6.126 MWh (16.784 kWh/day) 7.835 MWh (21.465 kWh/day) 1.709 MWh (4.681 kWh/day)
Lifetime Since PTO 36.882 MWh (17.228 kW/day) 41.163 MWh (19.227 kW/day) 4.280 MWh (1.999 kW/day)
Lifetime Since Install 36.916 MWh 41.743 MWh 4.826 MWh
Voltage/Current 247.9 V / 1.3 A 248.0 V / 4.5 A 247.9 V / 3.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 08/21/2025 23:54 (23.8 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 21.203 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.274 1.113 0.388 10.663 0.000 kW
1.090 kWh
0.000 kW
6.543 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.282 1.067 0.365 10.122
03 - 202224****** IQ7+M [0] ---- 0.000 0.287 1.106 0.386 10.531
04 - 202232****** IQ7+ [0] ---- 0.000 0.279 1.110 0.385 10.730
05 - 202244****** IQ7+M [0] ---- 0.000 0.276 1.060 0.358 9.824
06 - 202245****** IQ7+M [0] ---- 0.000 0.278 1.087 0.374 10.272
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.293 1.075 0.337 10.137 0.000 kW
1.090 kWh
0.000 kW
5.449 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.286 1.092 0.347 10.219
09 - 202217****** IQ7+ [0] ---- 0.000 0.278 1.086 0.346 10.204
10 - 202244****** IQ7+M [0] ---- 0.000 0.294 1.092 0.348 10.365
11 - 202224****** IQ7+M [0] ---- 0.000 0.292 1.104 0.350 10.568
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.229 0.903 0.363 9.114 0.000 kW
0.940 kWh
0.000 kW
3.761 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.236 0.927 0.386 9.191
14 - 202216****** IQ7+ [0] ---- 0.000 0.235 0.965 0.400 9.561
15 - 202245****** IQ7+M [0] ---- 0.000 0.242 0.966 0.400 9.604
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.725 kWh
0.230 kW
5.451 kWh
17 - 122214****** IQ7PD [0] ---- 0.230 0.231 5.451 5.505 38.465
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 0.64 V Voltage Charge 52.21 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.8 °C / 28.5 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-08-21 23:55
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.48 V Current/Power -6.40 A (-0.336 kW)
Remain Capacity/Energy 272.2 Ah (13.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 45.9 % State Of Health 98.9 %
Run Time 1d 18h 31m to empty Report Date 2025-08-21 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.