Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 4.830 kW
05/23/2026 23:45 (2187 days) Production Consumption NET Usage
Now 0.000 kW 4.830 kW 4.830 kW
Today 4.807 kWh (0.202 kW) 6.950 kWh (0.292 kW) 2.143 kWh (0.090 kW)
  - This Week 160.179 kWh (22.913 kWh/day) 156.219 kWh (22.346 kWh/day) -3.960 kWh (-0.566 kWh/day)
  - This Month 561.995 kWh (24.445 kWh/day) 355.941 kWh (15.482 kWh/day) -206.054 kWh (-8.963 kWh/day)
  - This Year 2.515 MWh (17.589 kWh/day) 2.416 MWh (16.894 kWh/day) -0.099 MWh (-0.695 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 160.179 kWh (22.883 kWh/day) 156.288 kWh (22.327 kWh/day) -3.891 kWh (-0.556 kWh/day)
Last 30 Days (04/23/2026) 698.958 kWh (23.299 kWh/day) 420.547 kWh (14.018 kWh/day) -278.411 kWh (-9.280 kWh/day)
Last One Year 6.381 MWh (17.483 kWh/day) 7.782 MWh (21.320 kWh/day) 1.400 MWh (3.836 kWh/day)
Lifetime Since PTO 38.081 MWh (17.404 kW/day) 41.926 MWh (19.162 kW/day) 3.846 MWh (1.758 kW/day)
Lifetime Since Install 38.115 MWh 42.506 MWh 4.392 MWh
Voltage/Current 248.4 V / 0.0 A 248.3 V / 19.5 A 248.3 V / 19.5 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/15/2025 23:50 (11.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.895 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.260 1.118 0.590 5.636 0.000 kW
1.081 kWh
0.000 kW
6.488 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.244 1.051 0.563 5.371
03 - 202224****** IQ7+M [0] ---- 0.000 0.254 1.078 0.586 5.564
04 - 202232****** IQ7+ [0] ---- 0.000 0.261 1.083 0.588 5.567
05 - 202244****** IQ7+M [0] ---- 0.000 0.250 1.045 0.556 5.324
06 - 202245****** IQ7+M [0] ---- 0.000 0.262 1.113 0.574 5.455
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.295 1.247 0.552 5.539 0.000 kW
1.304 kWh
0.000 kW
6.522 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.293 1.295 0.556 5.854
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 1.317 0.555 5.924
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.329 0.558 5.980
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.333 0.555 6.002
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.154 0.673 0.507 3.804 0.000 kW
0.721 kWh
0.000 kW
2.885 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.158 0.718 0.534 4.047
14 - 202216****** IQ7+ [0] ---- 0.000 0.149 0.747 0.564 4.239
15 - 202245****** IQ7+M [0] ---- 0.000 0.164 0.746 0.566 4.235
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 26.954
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 0.55 V Voltage Charge 52.49 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.1 °C / 25.8 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-10-15 23:56
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.68 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 254.1 Ah (13.0 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 42.8 % State Of Health 98.9 %
Run Time 7d 1h 24m to empty Report Date 2025-10-15 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.