Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.215 kW
04/07/2026 01:19 (2141 days) Production Consumption NET Usage
Now 0.316 kW 0.531 kW 0.215 kW
Today 0.421 kWh (0.317 kW) 0.655 kWh (0.493 kW) 0.234 kWh (0.176 kW)
  - This Week 36.339 kWh (17.680 kWh/day) 25.356 kWh (12.336 kWh/day) -10.983 kWh (-5.343 kWh/day)
  - This Month 88.944 kWh (14.688 kWh/day) 86.415 kWh (14.271 kWh/day) -2.529 kWh (-0.418 kWh/day)
  - This Year 1.318 MWh (13.725 kWh/day) 1.652 MWh (17.196 kWh/day) 0.333 MWh (3.471 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 107.026 kWh (15.289 kWh/day) 101.144 kWh (14.449 kWh/day) -5.882 kWh (-0.840 kWh/day)
Last 30 Days (03/08/2026) 590.733 kWh (19.691 kWh/day) 445.193 kWh (14.840 kWh/day) -145.540 kWh (-4.851 kWh/day)
Last One Year 6.128 MWh (16.789 kWh/day) 7.831 MWh (21.455 kWh/day) 1.703 MWh (4.667 kWh/day)
Lifetime Since PTO 36.884 MWh (17.227 kW/day) 41.163 MWh (19.225 kW/day) 4.278 MWh (1.998 kW/day)
Lifetime Since Install 36.918 MWh 41.742 MWh 4.825 MWh
Voltage/Current 249.5 V / 1.3 A 249.6 V / 2.1 A 249.5 V / 0.9 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/12/2025 23:56 (21.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.577 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.070 0.252 0.320 8.844 0.000 kW
0.244 kWh
0.000 kW
1.463 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.066 0.238 0.302 8.450
03 - 202224****** IQ7+M [0] ---- 0.000 0.069 0.249 0.318 8.735
04 - 202232****** IQ7+ [0] ---- 0.000 0.070 0.249 0.316 8.781
05 - 202244****** IQ7+M [0] ---- 0.000 0.065 0.233 0.294 8.378
06 - 202245****** IQ7+M [0] ---- 0.000 0.068 0.242 0.308 8.535
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.061 0.229 0.289 8.726 0.000 kW
0.228 kWh
0.000 kW
1.141 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.062 0.227 0.289 9.420
09 - 202217****** IQ7+ [0] ---- 0.000 0.061 0.228 0.289 9.569
10 - 202244****** IQ7+M [0] ---- 0.000 0.062 0.230 0.292 9.636
11 - 202224****** IQ7+M [0] ---- 0.000 0.062 0.227 0.289 9.707
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.063 0.226 0.289 5.630 0.000 kW
0.248 kWh
0.000 kW
0.990 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.068 0.241 0.308 5.963
14 - 202216****** IQ7+ [0] ---- 0.000 0.070 0.261 0.325 6.174
15 - 202245****** IQ7+M [0] ---- 0.000 0.070 0.262 0.327 6.162
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
2.492 kWh
0.000 kW
4.984 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.231 4.984 5.500 38.469
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 1.58 V Voltage Charge 52.24 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.5 °C / 25.8 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-10-12 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.46 V Current/Power -2.10 A (-0.110 kW)
Remain Capacity/Energy 211.2 Ah (10.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 35.6 % State Of Health 98.9 %
Run Time 4d 4h 34m to empty Report Date 2025-10-12 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.