Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.261 kW
07/27/2025 18:05 (1887 days) Production Consumption NET Usage
Now 0.515 kW 2.776 kW 2.261 kW
Today 11.216 kWh (0.619 kW) 19.413 kWh (1.072 kW) 8.197 kWh (0.452 kW)
  - This Week 11.216 kWh (14.860 kWh/day) 19.413 kWh (25.720 kWh/day) 8.197 kWh (10.860 kWh/day)
  - This Month 632.344 kWh (23.635 kWh/day) 1040.926 kWh (38.906 kWh/day) 408.582 kWh (15.271 kWh/day)
  - This Year 3.662 MWh (17.627 kWh/day) 4.168 MWh (20.063 kWh/day) 0.506 MWh (2.436 kWh/day)
Yesterday 26.728 kWh (1.113 kW) 39.650 kWh (1.651 kW) 12.922 kWh (0.538 kW)
Last 7 Days 169.271 kWh (24.185 kWh/day) 287.611 kWh (41.092 kWh/day) 118.340 kWh (16.908 kWh/day)
Last 30 Days 711.500 kWh (23.717 kWh/day) 1160.435 kWh (38.682 kWh/day) 448.935 kWh (14.965 kWh/day)
Last One Year 6.285 MWh (17.220 kWh/day) 6.722 MWh (18.417 kWh/day) 0.437 MWh (1.197 kWh/day)
Lifetime Since PTO 33.113 MWh (17.541 kW/day) 36.120 MWh (19.134 kW/day) 3.007 MWh (1.593 kW/day)
Lifetime Since Install 33.147 MWh 36.700 MWh 3.553 MWh
Voltage/Current 249.5 V / 2.1 A 249.5 V / 11.1 A 249.5 V / 9.1 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/31/2025 23:32 (12.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.629 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.252 0.956 0.400 4.481 0.000 kW
0.931 kWh
0.000 kW
5.588 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.245 0.915 0.376 4.334
03 - 202224****** IQ7+M [5] VCOP 0.000 0.234 0.928 0.397 4.495
04 - 202232****** IQ7+ [5] VCOP 0.000 0.251 0.950 0.395 5.039
05 - 202244****** IQ7+M [5] VCOP 0.000 0.239 0.916 0.364 6.240
06 - 202245****** IQ7+M [5] VCOP 0.000 0.248 0.923 0.382 4.399
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.262 0.951 0.353 7.120 0.000 kW
0.947 kWh
0.000 kW
4.733 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.247 0.965 0.359 5.904
09 - 202217****** IQ7+ [5] VCOP 0.000 0.245 0.955 0.357 7.385
10 - 202244****** IQ7+M [5] VCOP 0.000 0.238 0.890 0.359 4.320
11 - 202224****** IQ7+M [5] VCOP 0.000 0.261 0.973 0.362 7.711
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.184 0.790 0.376 6.116 0.000 kW
0.827 kWh
0.000 kW
3.307 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.191 0.824 0.397 6.711
14 - 202216****** IQ7+ [5] VCOP 0.000 0.189 0.848 0.412 6.899
15 - 202245****** IQ7+M [5] VCOP 0.000 0.193 0.845 0.411 6.864
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 1.59 V Voltage Charge 52.49 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 27.0 °C / 24.1 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-03-31 23:58
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.