Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.369 kW
05/22/2026 20:23 (2186 days) Production Consumption NET Usage
Now 0.000 kW 0.369 kW 0.369 kW
Today 29.595 kWh (1.450 kW) 4.189 kWh (0.205 kW) -25.406 kWh (-1.245 kW)
  - This Week 155.372 kWh (26.557 kWh/day) 148.353 kWh (25.357 kWh/day) -7.019 kWh (-1.200 kWh/day)
  - This Month 557.188 kWh (25.501 kWh/day) 348.075 kWh (15.930 kWh/day) -209.113 kWh (-9.570 kWh/day)
  - This Year 2.510 MWh (17.696 kWh/day) 2.408 MWh (16.974 kWh/day) -0.102 MWh (-0.722 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 188.290 kWh (26.899 kWh/day) 156.601 kWh (22.372 kWh/day) -31.689 kWh (-4.527 kWh/day)
Last 30 Days (04/22/2026) 721.023 kWh (24.034 kWh/day) 419.983 kWh (13.999 kWh/day) -301.040 kWh (-10.035 kWh/day)
Last One Year 6.392 MWh (17.512 kWh/day) 7.791 MWh (21.344 kWh/day) 1.399 MWh (3.833 kWh/day)
Lifetime Since PTO 38.076 MWh (17.411 kW/day) 41.919 MWh (19.168 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.110 MWh 42.499 MWh 4.389 MWh
Voltage/Current 249.1 V / 0.0 A 249.1 V / 1.5 A 249.1 V / 1.5 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/03/2023 23:43 (12.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.255 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.266 1.846 1.971 11.255 0.000 kW
1.774 kWh
0.000 kW
10.646 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.251 1.747 1.878 10.720
03 - 202224****** IQ7+M [0] ---- 0.000 0.259 1.808 1.952 11.164
04 - 202232****** IQ7+ [0] ---- 0.000 0.263 1.831 1.978 11.330
05 - 202244****** IQ7+M [0] ---- 0.000 0.253 1.680 1.803 10.376
06 - 202245****** IQ7+M [0] ---- 0.000 0.259 1.734 1.862 10.738
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.286 1.782 1.919 10.896 0.000 kW
1.827 kWh
0.000 kW
9.133 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.285 1.828 1.963 11.049
09 - 202217****** IQ7+ [0] ---- 0.000 0.282 1.799 1.945 10.922
10 - 202244****** IQ7+M [0] ---- 0.000 0.282 1.842 1.977 11.093
11 - 202224****** IQ7+M [0] ---- 0.000 0.288 1.882 2.018 11.311
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.206 1.495 1.606 9.355 0.000 kW
1.528 kWh
0.000 kW
6.111 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.210 1.509 1.617 9.479
14 - 202216****** IQ7+ [0] ---- 0.000 0.211 1.556 1.681 9.829
15 - 202245****** IQ7+M [0] ---- 0.000 0.211 1.551 1.682 9.851
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.683 kWh
0.000 kW
1.365 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.230 1.365 1.361 14.121
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 52.55 V Current/Power -4.58 A (-0.241 kW)
Remain Capacity/Energy 185.8 Ah (9.5 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 31.3 % State Of Health 98.9 %
Run Time 1d 16h 33m to empty Report Date 2023-09-03 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.