Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.146 kW
12/25/2025 09:37 (2038 days) Production Consumption NET Usage
Now 0.312 kW 0.166 kW -0.146 kW
Today 0.236 kWh (0.024 kW) 3.701 kWh (0.384 kW) 3.465 kWh (0.359 kW)
  - This Week 37.330 kWh (8.481 kWh/day) 59.416 kWh (13.498 kWh/day) 22.086 kWh (5.018 kWh/day)
  - This Month 212.236 kWh (8.698 kWh/day) 482.697 kWh (19.781 kWh/day) 270.461 kWh (11.084 kWh/day)
  - This Year 6.081 MWh (16.968 kWh/day) 7.399 MWh (20.644 kWh/day) 1.318 MWh (3.677 kWh/day)
Yesterday 13.231 kWh (0.551 kW) 14.841 kWh (0.619 kW) 1.610 kWh (0.067 kW)
Last 7 Days 65.241 kWh (9.320 kWh/day) 151.774 kWh (21.683 kWh/day) 86.533 kWh (12.362 kWh/day)
Last 30 Days 261.241 kWh (8.708 kWh/day) 616.792 kWh (20.559 kWh/day) 355.551 kWh (11.851 kWh/day)
Last One Year 6.140 MWh (16.823 kWh/day) 7.587 MWh (20.787 kWh/day) 1.447 MWh (3.964 kWh/day)
Lifetime Since PTO 35.532 MWh (17.431 kW/day) 39.352 MWh (19.305 kW/day) 3.820 MWh (1.874 kW/day)
Lifetime Since Install 35.566 MWh 39.932 MWh 4.366 MWh
Voltage/Current 249.6 V / 1.3 A 249.5 V / 0.7 A 249.6 V / -0.6 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/22/2023 23:19 (14.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.164 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.789 1.639 13.469 0.000 kW
1.716 kWh
0.000 kW
10.295 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.284 1.686 1.539 12.654
03 - 202224****** IQ7+M [5] VCOP 0.000 0.292 1.740 1.580 12.987
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.771 1.599 13.241
05 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.579 1.460 11.915
06 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.729 1.581 13.002
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.282 1.612 1.472 12.468 0.000 kW
1.622 kWh
0.000 kW
8.110 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.284 1.622 1.421 12.199
09 - 202217****** IQ7+ [5] VCOP 0.000 0.281 1.620 1.459 12.380
10 - 202244****** IQ7+M [5] VCOP 0.000 0.279 1.619 1.493 12.546
11 - 202224****** IQ7+M [5] VCOP 0.000 0.284 1.638 1.509 12.725
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.263 1.706 1.556 12.577 0.000 kW
1.768 kWh
0.000 kW
7.070 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.266 1.753 1.585 12.580
14 - 202216****** IQ7+ [5] VCOP 0.000 0.269 1.802 1.639 13.122
15 - 202245****** IQ7+M [5] VCOP 0.000 0.270 1.810 1.638 13.132
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.845 kWh
0.000 kW
1.689 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.230 1.689 1.693 11.958
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 52.42 V Current/Power -4.56 A (-0.239 kW)
Remain Capacity/Energy 257.1 Ah (13.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 42.9 % State Of Health 100.0 %
Run Time 2d 8h 22m to empty Report Date 2023-05-22 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.