Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.431 kW
05/23/2026 10:35 (2187 days) Production Consumption NET Usage
Now 0.635 kW 0.204 kW -0.431 kW
Today 1.453 kWh (0.137 kW) 0.738 kWh (0.070 kW) -0.715 kWh (-0.067 kW)
  - This Week 156.825 kWh (24.344 kWh/day) 150.007 kWh (23.286 kWh/day) -6.818 kWh (-1.058 kWh/day)
  - This Month 558.641 kWh (24.893 kWh/day) 349.729 kWh (15.584 kWh/day) -208.912 kWh (-9.309 kWh/day)
  - This Year 2.512 MWh (17.633 kWh/day) 2.409 MWh (16.915 kWh/day) -0.102 MWh (-0.718 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 183.846 kWh (26.264 kWh/day) 155.907 kWh (22.272 kWh/day) -27.939 kWh (-3.991 kWh/day)
Last 30 Days (04/23/2026) 717.336 kWh (23.911 kWh/day) 419.339 kWh (13.978 kWh/day) -297.997 kWh (-9.933 kWh/day)
Last One Year 6.391 MWh (17.509 kWh/day) 7.785 MWh (21.328 kWh/day) 1.394 MWh (3.819 kWh/day)
Lifetime Since PTO 38.077 MWh (17.407 kW/day) 41.920 MWh (19.164 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.111 MWh 42.500 MWh 4.389 MWh
Voltage/Current 248.9 V / 2.6 A 248.7 V / 0.8 A 248.8 V / -1.7 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/24/2023 23:19 (10.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.024 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.261 1.139 1.471 5.763 0.000 kW
1.122 kWh
0.000 kW
6.730 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.249 1.093 1.397 5.472
03 - 202224****** IQ7+M [5] VCOP 0.000 0.257 1.133 1.438 5.674
04 - 202232****** IQ7+ [5] VCOP 0.000 0.263 1.137 1.437 5.678
05 - 202244****** IQ7+M [5] VCOP 0.000 0.252 1.103 1.411 5.449
06 - 202245****** IQ7+M [5] VCOP 0.000 0.255 1.123 1.437 5.587
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.282 1.152 1.493 5.481 0.000 kW
1.292 kWh
0.000 kW
6.462 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.279 1.279 1.647 5.913
09 - 202217****** IQ7+ [5] VCOP 0.000 0.282 1.357 1.789 6.256
10 - 202244****** IQ7+M [5] VCOP 0.000 0.279 1.334 1.734 6.172
11 - 202224****** IQ7+M [5] VCOP 0.000 0.281 1.340 1.721 6.127
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.167 0.654 0.772 3.881 0.000 kW
0.708 kWh
0.000 kW
2.832 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.181 0.707 0.852 4.153
14 - 202216****** IQ7+ [5] VCOP 0.000 0.172 0.737 0.885 4.333
15 - 202245****** IQ7+M [5] VCOP 0.000 0.174 0.734 0.880 4.333
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 1.123
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.25 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 464.6 Ah (23.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 78.3 % State Of Health 98.9 %
Run Time 12d 21h 42m to empty Report Date 2023-10-24 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.