Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.070 kW
05/23/2026 01:59 (2187 days) Production Consumption NET Usage
Now 0.000 kW -0.070 kW -0.070 kW
Today 0.000 kWh (0.000 kW) 0.104 kWh (0.052 kW) 0.104 kWh (0.052 kW)
  - This Week 155.372 kWh (25.539 kWh/day) 149.373 kWh (24.552 kWh/day) -5.999 kWh (-0.986 kWh/day)
  - This Month 557.188 kWh (25.231 kWh/day) 349.095 kWh (15.808 kWh/day) -208.093 kWh (-9.423 kWh/day)
  - This Year 2.510 MWh (17.667 kWh/day) 2.409 MWh (16.953 kWh/day) -0.101 MWh (-0.714 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 188.290 kWh (26.899 kWh/day) 156.010 kWh (22.287 kWh/day) -32.280 kWh (-4.611 kWh/day)
Last 30 Days (04/23/2026) 721.023 kWh (24.034 kWh/day) 420.440 kWh (14.015 kWh/day) -300.583 kWh (-10.019 kWh/day)
Last One Year 6.392 MWh (17.512 kWh/day) 7.788 MWh (21.337 kWh/day) 1.396 MWh (3.826 kWh/day)
Lifetime Since PTO 38.076 MWh (17.409 kW/day) 41.920 MWh (19.167 kW/day) 3.844 MWh (1.757 kW/day)
Lifetime Since Install 38.110 MWh 42.500 MWh 4.390 MWh
Voltage/Current 250.0 V / 0.0 A 250.0 V / -0.3 A 250.0 V / -0.3 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/27/2024 23:36 (10.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.595 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.245 0.894 1.282 8.305 0.000 kW
0.872 kWh
0.000 kW
5.232 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.240 0.851 1.226 7.892
03 - 202224****** IQ7+M [0] ---- 0.000 0.245 0.887 1.268 8.184
04 - 202232****** IQ7+ [0] ---- 0.000 0.247 0.890 1.273 8.146
05 - 202244****** IQ7+M [0] ---- 0.000 0.241 0.844 1.221 7.823
06 - 202245****** IQ7+M [0] ---- 0.000 0.245 0.864 1.240 8.002
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.269 0.944 1.505 8.805 0.000 kW
0.946 kWh
0.000 kW
4.731 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.274 0.952 1.519 9.243
09 - 202217****** IQ7+ [0] ---- 0.000 0.267 0.944 1.504 9.342
10 - 202244****** IQ7+M [0] ---- 0.000 0.268 0.938 1.496 9.352
11 - 202224****** IQ7+M [0] ---- 0.000 0.270 0.953 1.515 9.388
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.161 0.615 0.611 4.725 0.000 kW
0.658 kWh
0.000 kW
2.632 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.167 0.655 0.688 5.217
14 - 202216****** IQ7+ [0] ---- 0.000 0.176 0.685 0.724 5.437
15 - 202245****** IQ7+M [0] ---- 0.000 0.174 0.678 0.713 5.398
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 7.809
Panel Layout Each Group Production
Last 7 days
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.