Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.185 kW
05/23/2026 04:35 (2187 days) Production Consumption NET Usage
Now 0.000 kW -0.185 kW -0.185 kW
Today 0.000 kWh (0.000 kW) 0.386 kWh (0.084 kW) 0.386 kWh (0.084 kW)
  - This Week 155.372 kWh (25.091 kWh/day) 149.655 kWh (24.168 kWh/day) -5.717 kWh (-0.923 kWh/day)
  - This Month 557.188 kWh (25.108 kWh/day) 349.377 kWh (15.744 kWh/day) -207.811 kWh (-9.364 kWh/day)
  - This Year 2.510 MWh (17.654 kWh/day) 2.409 MWh (16.943 kWh/day) -0.101 MWh (-0.711 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 188.290 kWh (26.899 kWh/day) 156.459 kWh (22.351 kWh/day) -31.831 kWh (-4.547 kWh/day)
Last 30 Days (04/23/2026) 721.023 kWh (24.034 kWh/day) 420.776 kWh (14.026 kWh/day) -300.247 kWh (-10.008 kWh/day)
Last One Year 6.392 MWh (17.512 kWh/day) 7.787 MWh (21.335 kWh/day) 1.396 MWh (3.824 kWh/day)
Lifetime Since PTO 38.076 MWh (17.409 kW/day) 41.920 MWh (19.166 kW/day) 3.844 MWh (1.757 kW/day)
Lifetime Since Install 38.110 MWh 42.500 MWh 4.390 MWh
Voltage/Current 250.5 V / 0.0 A 250.6 V / -0.7 A 250.6 V / -0.7 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/19/2024 23:19 (11.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.872 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.293 1.633 1.455 10.897 0.000 kW
1.589 kWh
0.000 kW
9.536 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.295 1.571 1.389 10.420
03 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.618 1.427 10.739
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.617 1.432 10.792
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.540 1.350 10.215
06 - 202245****** IQ7+M [0] ---- 0.000 0.288 1.556 1.383 10.398
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.292 1.469 1.327 10.663 0.000 kW
1.593 kWh
0.000 kW
7.967 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.293 1.621 1.453 11.436
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 1.620 1.455 11.394
10 - 202244****** IQ7+M [0] ---- 0.000 0.294 1.620 1.454 11.460
11 - 202224****** IQ7+M [0] ---- 0.000 0.295 1.638 1.470 11.613
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.245 1.287 1.098 7.383 0.000 kW
1.342 kWh
0.000 kW
5.369 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.230 1.335 1.143 7.692
14 - 202216****** IQ7+ [0] ---- 0.000 0.230 1.381 1.196 8.034
15 - 202245****** IQ7+M [0] ---- 0.000 0.227 1.366 1.182 7.948
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 3.006
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 52.56 V Current/Power -0.33 A (-17 W)
Remain Capacity/Energy 276.9 Ah (14.2 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 46.7 % State Of Health 98.9 %
Run Time 34d 23h 12m to empty Report Date 2024-03-19 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.