Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.186 kW
04/04/2026 15:04 (2138 days) Production Consumption NET Usage
Now 0.588 kW 0.402 kW -0.186 kW
Today 14.571 kWh (0.965 kW) 7.907 kWh (0.524 kW) -6.664 kWh (-0.442 kW)
  - This Week 122.264 kWh (18.445 kWh/day) 108.974 kWh (16.440 kWh/day) -13.290 kWh (-2.005 kWh/day)
  - This Month 49.899 kWh (13.752 kWh/day) 53.331 kWh (14.698 kWh/day) 3.432 kWh (0.946 kWh/day)
  - This Year 1.279 MWh (13.664 kWh/day) 1.619 MWh (17.288 kWh/day) 0.339 MWh (3.624 kWh/day)
Yesterday 18.529 kWh (0.772 kW) 13.745 kWh (0.573 kW) -4.784 kWh (-0.199 kW)
Last 7 Days 129.396 kWh (18.485 kWh/day) 116.384 kWh (16.626 kWh/day) -13.012 kWh (-1.859 kWh/day)
Last 30 Days (03/05/2026) 561.991 kWh (18.733 kWh/day) 453.834 kWh (15.128 kWh/day) -108.157 kWh (-3.605 kWh/day)
Last One Year 6.104 MWh (16.722 kWh/day) 7.835 MWh (21.467 kWh/day) 1.732 MWh (4.745 kWh/day)
Lifetime Since PTO 36.845 MWh (17.228 kW/day) 41.129 MWh (19.232 kW/day) 4.284 MWh (2.003 kW/day)
Lifetime Since Install 36.879 MWh 41.709 MWh 4.831 MWh
Voltage/Current 247.8 V / 2.4 A 247.8 V / 1.6 A 247.8 V / -0.8 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/01/2024 23:53 (15.4 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 7.350 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.091 0.281 0.197 1.522 0.000 kW
0.267 kWh
0.000 kW
1.605 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.084 0.258 0.179 1.401
03 - 202224****** IQ7+M [5] VCOP 0.000 0.090 0.277 0.194 1.507
04 - 202232****** IQ7+ [5] VCOP 0.000 0.090 0.275 0.192 1.492
05 - 202244****** IQ7+M [5] VCOP 0.000 0.086 0.252 0.174 1.368
06 - 202245****** IQ7+M [5] VCOP 0.000 0.088 0.261 0.181 1.416
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.093 0.252 0.175 1.362 0.000 kW
0.256 kWh
0.000 kW
1.279 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.090 0.258 0.179 1.391
09 - 202217****** IQ7+ [5] VCOP 0.000 0.089 0.255 0.176 1.371
10 - 202244****** IQ7+M [5] VCOP 0.000 0.093 0.256 0.176 1.378
11 - 202224****** IQ7+M [5] VCOP 0.000 0.094 0.259 0.178 1.392
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.060 0.245 0.171 1.332 0.000 kW
0.266 kWh
0.000 kW
1.064 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.069 0.264 0.187 1.439
14 - 202216****** IQ7+ [5] VCOP 0.000 0.072 0.278 0.198 1.522
15 - 202245****** IQ7+M [5] VCOP 0.000 0.072 0.277 0.198 1.518
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.115 kW
1.702 kWh
0.230 kW
3.403 kWh
17 - 122214****** IQ7PD [4] VCOP 0.230 0.230 3.403 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 52.48 V Current/Power -5.40 A (-0.283 kW)
Remain Capacity/Energy 324.6 Ah (16.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 54.7 % State Of Health 98.9 %
Run Time 2d 12h 6m to empty Report Date 2024-02-01 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.45 V Cell (MIN/MAX) 3.270 V / 3.285 V (0.015 V)
Current/Power -1.58 A (-82 W) Runtime 2d 20h 29m to empty
Remain Capacity/Energy 108.2 Ah (5.5 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 54.7 % State Of Health 98.8 %
Temperature 15.5 °C Cycle 131
MOSFET CFET = ON, DFET = ON Reported 2024-02-01 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.270 V 3.272 V 3.273 V 3.273 V 3.277 V 3.274 V 3.276 V 3.277 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.280 V 3.278 V 3.281 V 3.280 V 3.283 V 3.283 V 3.285 V 3.285 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt2_1.png". Check that the process running PHP has enough permission.