Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.786 kW
04/04/2026 23:43 (2138 days) Production Consumption NET Usage
Now 0.000 kW 0.786 kW 0.786 kW
Today 17.277 kWh (0.728 kW) 15.361 kWh (0.647 kW) -1.916 kWh (-0.081 kW)
  - This Week 124.970 kWh (17.882 kWh/day) 116.428 kWh (16.660 kWh/day) -8.542 kWh (-1.222 kWh/day)
  - This Month 52.605 kWh (13.189 kWh/day) 60.785 kWh (15.240 kWh/day) 8.180 kWh (2.051 kWh/day)
  - This Year 1.282 MWh (13.640 kWh/day) 1.626 MWh (17.301 kWh/day) 0.344 MWh (3.661 kWh/day)
Yesterday 18.529 kWh (0.772 kW) 13.745 kWh (0.573 kW) -4.784 kWh (-0.199 kW)
Last 7 Days 124.970 kWh (17.853 kWh/day) 116.518 kWh (16.645 kWh/day) -8.452 kWh (-1.207 kWh/day)
Last 30 Days (03/05/2026) 564.229 kWh (18.808 kWh/day) 453.591 kWh (15.120 kWh/day) -110.638 kWh (-3.688 kWh/day)
Last One Year 6.103 MWh (16.720 kWh/day) 7.837 MWh (21.471 kWh/day) 1.734 MWh (4.751 kWh/day)
Lifetime Since PTO 36.848 MWh (17.227 kW/day) 41.137 MWh (19.232 kW/day) 4.289 MWh (2.005 kW/day)
Lifetime Since Install 36.882 MWh 41.717 MWh 4.835 MWh
Voltage/Current 250.4 V / 0.0 A 250.3 V / 3.1 A 250.3 V / 3.1 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/07/2024 23:40 (10.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.400 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.246 1.330 1.338 5.972 0.000 kW
1.288 kWh
0.000 kW
7.730 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.236 1.255 1.270 5.661
03 - 202224****** IQ7+M [0] ---- 0.000 0.242 1.292 1.318 5.858
04 - 202232****** IQ7+ [0] ---- 0.000 0.245 1.297 1.307 5.836
05 - 202244****** IQ7+M [0] ---- 0.000 0.237 1.258 1.273 5.668
06 - 202245****** IQ7+M [0] ---- 0.000 0.240 1.299 1.309 5.779
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.290 1.390 1.422 6.185 0.000 kW
1.568 kWh
0.000 kW
7.839 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.292 1.566 1.596 6.903
09 - 202217****** IQ7+ [0] ---- 0.000 0.291 1.653 1.705 7.379
10 - 202244****** IQ7+M [0] ---- 0.000 0.287 1.630 1.676 7.259
11 - 202224****** IQ7+M [0] ---- 0.000 0.292 1.600 1.642 7.096
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.126 0.632 0.600 2.925 0.000 kW
0.708 kWh
0.000 kW
2.831 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.131 0.715 0.700 3.373
14 - 202216****** IQ7+ [0] ---- 0.000 0.136 0.745 0.728 3.519
15 - 202245****** IQ7+M [0] ---- 0.000 0.135 0.739 0.723 3.489
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 21.971
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.21 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 521.7 Ah (26.7 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 88.0 % State Of Health 98.9 %
Run Time 24d 3h 40m to empty Report Date 2024-02-07 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.21 V Cell (MIN/MAX) 3.319 V / 3.330 V (0.011 V)
Current/Power -0.28 A (-14 W) Runtime 25d 21h 4m to empty
Remain Capacity/Energy 173.9 Ah (8.9 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 88.0 % State Of Health 98.8 %
Temperature 16.5 °C Cycle 132
MOSFET CFET = ON, DFET = ON Reported 2024-02-07 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.319 V 3.321 V 3.321 V 3.323 V 3.323 V 3.324 V 3.324 V 3.324 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.326 V 3.326 V 3.326 V 3.327 V 3.328 V 3.330 V 3.330 V 3.330 V
pack voltage and current cell voltages
pack temperature
Voltage 53.20 V Cell (MIN/MAX) 3.324 V / 3.325 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.0 Ah (5.1 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 99.5 %
Temperature 18.6 °C Cycle 73
MOSFET CFET = ON, DFET = ON Reported 2024-02-07 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.324 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.324 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V
pack voltage and current cell voltages
pack temperature
Voltage 53.23 V Cell (MIN/MAX) 3.326 V / 3.328 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.0 Ah (5.1 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 99.5 %
Temperature 17.5 °C Cycle 76
MOSFET CFET = ON, DFET = ON Reported 2024-02-07 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.326 V 3.328 V 3.327 V 3.326 V 3.327 V 3.326 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.328 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V
pack voltage and current cell voltages
pack temperature
Voltage 53.20 V Cell (MIN/MAX) 3.323 V / 3.325 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.0 Ah (5.1 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 99.5 %
Temperature 17.6 °C Cycle 78
MOSFET CFET = ON, DFET = ON Reported 2024-02-07 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.325 V 3.325 V 3.323 V 3.325 V 3.324 V 3.323 V 3.324 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.323 V 3.325 V 3.325 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt2_4.png". Check that the process running PHP has enough permission.