Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.090 kW
05/23/2026 06:21 (2187 days) Production Consumption NET Usage
Now 0.057 kW -0.033 kW -0.090 kW
Today 0.013 kWh (0.002 kW) 0.364 kWh (0.057 kW) 0.351 kWh (0.055 kW)
  - This Week 155.385 kWh (24.799 kWh/day) 149.633 kWh (23.881 kWh/day) -5.752 kWh (-0.918 kWh/day)
  - This Month 557.201 kWh (25.026 kWh/day) 349.355 kWh (15.691 kWh/day) -207.846 kWh (-9.335 kWh/day)
  - This Year 2.510 MWh (17.645 kWh/day) 2.409 MWh (16.934 kWh/day) -0.101 MWh (-0.711 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 188.246 kWh (26.892 kWh/day) 156.296 kWh (22.328 kWh/day) -31.950 kWh (-4.564 kWh/day)
Last 30 Days (04/23/2026) 721.031 kWh (24.034 kWh/day) 420.411 kWh (14.014 kWh/day) -300.620 kWh (-10.021 kWh/day)
Last One Year 6.392 MWh (17.512 kWh/day) 7.787 MWh (21.334 kWh/day) 1.395 MWh (3.822 kWh/day)
Lifetime Since PTO 38.076 MWh (17.408 kW/day) 41.920 MWh (19.165 kW/day) 3.844 MWh (1.757 kW/day)
Lifetime Since Install 38.110 MWh 42.500 MWh 4.390 MWh
Voltage/Current 251.0 V / 0.2 A 250.9 V / -0.1 A 251.0 V / -0.4 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/10/2024 23:44 (19.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.765 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.292 1.289 1.986 9.307 0.000 kW
1.250 kWh
0.000 kW
7.502 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.284 1.228 1.892 8.925
03 - 202224****** IQ7+M [5] VCOP 0.000 0.293 1.276 1.965 9.242
04 - 202232****** IQ7+ [5] VCOP 0.000 0.292 1.282 1.991 9.291
05 - 202244****** IQ7+M [5] VCOP 0.000 0.275 1.186 1.765 8.575
06 - 202245****** IQ7+M [5] VCOP 0.000 0.276 1.242 1.821 8.826
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.289 1.187 1.886 8.964 0.000 kW
1.219 kWh
0.000 kW
6.095 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.232 1.979 9.099
09 - 202217****** IQ7+ [5] VCOP 0.000 0.291 1.223 1.951 8.986
10 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.219 1.952 9.131
11 - 202224****** IQ7+M [5] VCOP 0.000 0.291 1.235 1.988 9.274
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.216 1.125 1.574 7.751 0.000 kW
1.183 kWh
0.000 kW
4.732 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.229 1.170 1.601 7.968
14 - 202216****** IQ7+ [5] VCOP 0.000 0.230 1.219 1.680 8.338
15 - 202245****** IQ7+M [5] VCOP 0.000 0.225 1.218 1.673 8.294
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
1.718 kWh
0.000 kW
3.435 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.230 3.435 5.488 38.449
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.31 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 397.5 Ah (20.4 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 67.0 % State Of Health 98.9 %
Run Time 11d 1h 0m to empty Report Date 2024-04-10 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.