Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.548 kW
04/05/2026 11:46 (2139 days) Production Consumption NET Usage
Now 0.091 kW 0.639 kW 0.548 kW
Today 1.831 kWh (0.155 kW) 9.148 kWh (0.776 kW) 7.317 kWh (0.621 kW)
  - This Week 1.831 kWh (3.730 kWh/day) 9.148 kWh (18.635 kWh/day) 7.317 kWh (14.905 kWh/day)
  - This Month 54.436 kWh (12.121 kWh/day) 70.207 kWh (15.633 kWh/day) 15.771 kWh (3.512 kWh/day)
  - This Year 1.284 MWh (13.587 kWh/day) 1.636 MWh (17.309 kWh/day) 0.352 MWh (3.722 kWh/day)
Yesterday 17.277 kWh (0.720 kW) 15.635 kWh (0.651 kW) -1.642 kWh (-0.068 kW)
Last 7 Days 119.225 kWh (17.032 kWh/day) 120.840 kWh (17.263 kWh/day) 1.615 kWh (0.231 kWh/day)
Last 30 Days (03/06/2026) 564.437 kWh (18.815 kWh/day) 456.263 kWh (15.209 kWh/day) -108.174 kWh (-3.606 kWh/day)
Last One Year 6.103 MWh (16.721 kWh/day) 7.839 MWh (21.477 kWh/day) 1.736 MWh (4.756 kWh/day)
Lifetime Since PTO 36.850 MWh (17.224 kW/day) 41.146 MWh (19.232 kW/day) 4.297 MWh (2.008 kW/day)
Lifetime Since Install 36.883 MWh 41.726 MWh 4.843 MWh
Voltage/Current 248.7 V / 0.4 A 248.9 V / 2.6 A 248.8 V / 2.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/27/2024 23:50 (13.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.764 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.294 1.491 2.285 13.535 0.000 kW
1.427 kWh
0.000 kW
8.561 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.290 1.402 2.160 12.878
03 - 202224****** IQ7+M [5] VCOP 0.000 0.290 1.466 2.254 13.363
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.504 2.302 13.550
05 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.299 2.038 12.262
06 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.399 2.168 12.928
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 1.310 2.196 13.018 0.000 kW
1.340 kWh
0.000 kW
6.700 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.351 2.160 12.761
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.343 2.145 12.677
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.340 2.197 13.005
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.356 2.255 13.337
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.273 1.551 1.994 11.573 0.000 kW
1.626 kWh
0.000 kW
6.503 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.286 1.615 2.002 11.661
14 - 202216****** IQ7+ [5] VCOP 0.000 0.276 1.666 2.116 12.293
15 - 202245****** IQ7+M [5] VCOP 0.000 0.289 1.671 2.113 12.244
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.415
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 51.97 V Current/Power -3.21 A (-0.167 kW)
Remain Capacity/Energy 122.4 Ah (6.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 20.6 % State Of Health 98.9 %
Run Time 1d 14h 7m to empty Report Date 2024-04-27 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.