Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.049 kW
04/09/2026 04:30 (2143 days) Production Consumption NET Usage
Now 0.317 kW 0.268 kW -0.049 kW
Today 1.428 kWh (0.317 kW) 2.100 kWh (0.466 kW) 0.672 kWh (0.149 kW)
  - This Week 112.432 kWh (26.847 kWh/day) 58.732 kWh (14.024 kWh/day) -53.700 kWh (-12.823 kWh/day)
  - This Month 165.037 kWh (20.156 kWh/day) 119.791 kWh (14.630 kWh/day) -45.246 kWh (-5.526 kWh/day)
  - This Year 1.394 MWh (14.202 kWh/day) 1.685 MWh (17.162 kWh/day) 0.291 MWh (2.960 kWh/day)
Yesterday 39.481 kWh (1.645 kW) 21.070 kWh (0.878 kW) -18.411 kWh (-0.767 kW)
Last 7 Days 152.328 kWh (21.761 kWh/day) 100.895 kWh (14.414 kWh/day) -51.433 kWh (-7.348 kWh/day)
Last 30 Days (03/10/2026) 630.645 kWh (21.021 kWh/day) 449.776 kWh (14.993 kWh/day) -180.869 kWh (-6.029 kWh/day)
Last One Year 6.171 MWh (16.908 kWh/day) 7.833 MWh (21.460 kWh/day) 1.662 MWh (4.552 kWh/day)
Lifetime Since PTO 36.960 MWh (17.245 kW/day) 41.196 MWh (19.222 kW/day) 4.236 MWh (1.976 kW/day)
Lifetime Since Install 36.994 MWh 41.776 MWh 4.782 MWh
Voltage/Current 251.4 V / 1.3 A 251.3 V / 1.1 A 251.4 V / -0.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/21/2024 23:32 (14.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.322 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.295 1.883 2.086 14.419 0.000 kW
1.760 kWh
0.000 kW
10.561 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.285 1.744 1.946 13.479
03 - 202224****** IQ7+M [0] ---- 0.000 0.293 1.773 1.981 13.761
04 - 202232****** IQ7+ [0] ---- 0.000 0.295 1.801 2.018 14.019
05 - 202244****** IQ7+M [0] ---- 0.000 0.283 1.564 1.789 12.284
06 - 202245****** IQ7+M [0] ---- 0.000 0.286 1.795 2.000 13.854
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.277 1.645 1.881 12.960 0.000 kW
1.645 kWh
0.000 kW
8.224 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.279 1.640 1.795 12.495
09 - 202217****** IQ7+ [0] ---- 0.000 0.279 1.637 1.830 12.656
10 - 202244****** IQ7+M [0] ---- 0.000 0.275 1.635 1.877 12.906
11 - 202224****** IQ7+M [0] ---- 0.000 0.283 1.667 1.925 13.200
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.250 1.817 1.926 13.683 0.000 kW
1.884 kWh
0.000 kW
7.536 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.259 1.869 1.930 13.822
14 - 202216****** IQ7+ [0] ---- 0.000 0.264 1.926 2.045 14.548
15 - 202245****** IQ7+M [0] ---- 0.000 0.263 1.924 2.044 14.547
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.20 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 536.4 Ah (27.5 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 90.4 % State Of Health 98.9 %
Run Time 14d 21h 36m to empty Report Date 2024-06-21 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.