Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.036 kW
04/09/2026 06:06 (2143 days) Production Consumption NET Usage
Now 0.317 kW 0.353 kW 0.036 kW
Today 1.935 kWh (0.317 kW) 2.809 kWh (0.460 kW) 0.874 kWh (0.143 kW)
  - This Week 112.939 kWh (26.545 kWh/day) 59.441 kWh (13.971 kWh/day) -53.498 kWh (-12.574 kWh/day)
  - This Month 165.544 kWh (20.054 kWh/day) 120.500 kWh (14.598 kWh/day) -45.044 kWh (-5.457 kWh/day)
  - This Year 1.395 MWh (14.197 kWh/day) 1.686 MWh (17.158 kWh/day) 0.291 MWh (2.960 kWh/day)
Yesterday 39.481 kWh (1.645 kW) 21.070 kWh (0.878 kW) -18.411 kWh (-0.767 kW)
Last 7 Days 152.835 kWh (21.834 kWh/day) 100.962 kWh (14.423 kWh/day) -51.873 kWh (-7.410 kWh/day)
Last 30 Days (03/10/2026) 631.152 kWh (21.038 kWh/day) 449.823 kWh (14.994 kWh/day) -181.329 kWh (-6.044 kWh/day)
Last One Year 6.172 MWh (16.909 kWh/day) 7.833 MWh (21.459 kWh/day) 1.661 MWh (4.550 kWh/day)
Lifetime Since PTO 36.961 MWh (17.245 kW/day) 41.197 MWh (19.222 kW/day) 4.236 MWh (1.976 kW/day)
Lifetime Since Install 36.995 MWh 41.777 MWh 4.782 MWh
Voltage/Current 250.4 V / 1.3 A 250.2 V / 1.4 A 250.3 V / 0.1 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/05/2024 23:54 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 30.072 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.287 1.727 0.902 9.726 0.000 kW
1.639 kWh
0.000 kW
9.836 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.274 1.604 0.859 9.161
03 - 202224****** IQ7+M [0] ---- 0.000 0.285 1.668 0.891 9.505
04 - 202232****** IQ7+ [0] ---- 0.000 0.293 1.718 0.898 9.642
05 - 202244****** IQ7+M [0] ---- 0.000 0.277 1.488 0.849 8.696
06 - 202245****** IQ7+M [0] ---- 0.000 0.283 1.631 0.874 9.347
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.282 1.564 0.853 9.067 0.000 kW
1.580 kWh
0.000 kW
7.901 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.284 1.594 0.832 8.897
09 - 202217****** IQ7+ [0] ---- 0.000 0.282 1.578 0.828 8.927
10 - 202244****** IQ7+M [0] ---- 0.000 0.280 1.568 0.853 9.087
11 - 202224****** IQ7+M [0] ---- 0.000 0.286 1.598 0.871 9.226
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.234 1.648 0.757 8.610 0.000 kW
1.710 kWh
0.000 kW
6.839 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.241 1.682 0.792 8.780
14 - 202216****** IQ7+ [0] ---- 0.000 0.248 1.755 0.824 9.239
15 - 202245****** IQ7+M [0] ---- 0.000 0.245 1.754 0.822 9.225
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.748 kWh
0.230 kW
5.496 kWh
17 - 122214****** IQ7PD [0] ---- 0.230 0.230 5.496 5.460 21.853
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 52.55 V Current/Power -5.50 A (-0.289 kW)
Remain Capacity/Energy 221.4 Ah (11.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 37.3 % State Of Health 98.9 %
Run Time 1d 16h 15m to empty Report Date 2024-08-05 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.