Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.247 kW
04/05/2026 17:32 (2139 days) Production Consumption NET Usage
Now 0.415 kW 0.662 kW 0.247 kW
Today 4.129 kWh (0.235 kW) 14.038 kWh (0.800 kW) 9.909 kWh (0.565 kW)
  - This Week 4.129 kWh (5.646 kWh/day) 14.038 kWh (19.195 kWh/day) 9.909 kWh (13.549 kWh/day)
  - This Month 56.734 kWh (11.991 kWh/day) 75.097 kWh (15.872 kWh/day) 18.363 kWh (3.881 kWh/day)
  - This Year 1.286 MWh (13.577 kWh/day) 1.640 MWh (17.317 kWh/day) 0.354 MWh (3.740 kWh/day)
Yesterday 17.277 kWh (0.720 kW) 15.635 kWh (0.651 kW) -1.642 kWh (-0.068 kW)
Last 7 Days 101.886 kWh (14.555 kWh/day) 103.196 kWh (14.742 kWh/day) 1.310 kWh (0.187 kWh/day)
Last 30 Days (03/06/2026) 564.632 kWh (18.821 kWh/day) 454.294 kWh (15.143 kWh/day) -110.338 kWh (-3.678 kWh/day)
Last One Year 6.104 MWh (16.722 kWh/day) 7.841 MWh (21.482 kWh/day) 1.737 MWh (4.760 kWh/day)
Lifetime Since PTO 36.852 MWh (17.223 kW/day) 41.151 MWh (19.232 kW/day) 4.299 MWh (2.009 kW/day)
Lifetime Since Install 36.886 MWh 41.731 MWh 4.845 MWh
Voltage/Current 249.4 V / 1.7 A 249.4 V / 2.7 A 249.4 V / 1.0 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/03/2024 23:57 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 33.683 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.283 1.986 1.779 8.704 0.000 kW
1.923 kWh
0.000 kW
11.538 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.268 1.889 1.688 8.251
03 - 202224****** IQ7+M [5] VCOP 0.000 0.276 1.968 1.738 8.570
04 - 202232****** IQ7+ [5] VCOP 0.000 0.280 1.996 1.747 8.639
05 - 202244****** IQ7+M [5] VCOP 0.000 0.267 1.823 1.694 8.080
06 - 202245****** IQ7+M [5] VCOP 0.000 0.273 1.876 1.731 8.357
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.291 1.969 1.831 8.526 0.000 kW
2.010 kWh
0.000 kW
10.049 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 2.016 1.803 8.521
09 - 202217****** IQ7+ [5] VCOP 0.000 0.290 1.965 1.785 8.422
10 - 202244****** IQ7+M [5] VCOP 0.000 0.287 2.027 1.824 8.578
11 - 202224****** IQ7+M [5] VCOP 0.000 0.294 2.072 1.854 8.719
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.218 1.592 1.259 6.927 0.000 kW
1.650 kWh
0.000 kW
6.601 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.225 1.621 1.269 7.131
14 - 202216****** IQ7+ [5] VCOP 0.000 0.230 1.698 1.338 7.473
15 - 202245****** IQ7+M [5] VCOP 0.000 0.230 1.690 1.325 7.450
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.747 kWh
0.230 kW
5.495 kWh
17 - 122214****** IQ7PD [5] VCOP 0.230 0.230 5.495 5.492 16.865
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 0.47 V Voltage Charge 52.46 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.8 °C / 28.1 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-09-03 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.72 V Current/Power -6.34 A (-0.334 kW)
Remain Capacity/Energy 355.0 Ah (18.2 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 59.9 % State Of Health 98.9 %
Run Time 2d 7h 59m to empty Report Date 2024-09-03 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.