Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.907 kW
12/26/2025 18:19 (2039 days) Production Consumption NET Usage
Now 0.000 kW 0.907 kW 0.907 kW
Today 5.294 kWh (0.289 kW) 10.110 kWh (0.551 kW) 4.816 kWh (0.263 kW)
  - This Week 49.422 kWh (8.575 kWh/day) 81.673 kWh (14.170 kWh/day) 32.251 kWh (5.596 kWh/day)
  - This Month 224.328 kWh (8.707 kWh/day) 504.954 kWh (19.599 kWh/day) 280.626 kWh (10.892 kWh/day)
  - This Year 6.093 MWh (16.937 kWh/day) 7.421 MWh (20.628 kWh/day) 1.328 MWh (3.691 kWh/day)
Yesterday 7.034 kWh (0.293 kW) 15.848 kWh (0.661 kW) 8.814 kWh (0.367 kW)
Last 7 Days 59.917 kWh (8.560 kWh/day) 105.329 kWh (15.048 kWh/day) 45.412 kWh (6.488 kWh/day)
Last 30 Days 264.277 kWh (8.809 kWh/day) 620.513 kWh (20.684 kWh/day) 356.236 kWh (11.875 kWh/day)
Last One Year 6.142 MWh (16.828 kWh/day) 7.583 MWh (20.776 kWh/day) 1.441 MWh (3.948 kWh/day)
Lifetime Since PTO 35.544 MWh (17.425 kW/day) 39.374 MWh (19.303 kW/day) 3.830 MWh (1.878 kW/day)
Lifetime Since Install 35.578 MWh 39.954 MWh 4.376 MWh
Voltage/Current 249.5 V / 0.0 A 249.7 V / 3.6 A 249.6 V / 3.6 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/09/2024 23:53 (9.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.194 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.203 0.967 1.117 7.389 0.000 kW
0.934 kWh
0.000 kW
5.605 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.193 0.911 1.061 7.018
03 - 202224****** IQ7+M [0] ---- 0.000 0.199 0.957 1.091 7.232
04 - 202232****** IQ7+ [0] ---- 0.000 0.199 0.889 1.091 7.265
05 - 202244****** IQ7+M [0] ---- 0.000 0.193 0.930 1.069 7.072
06 - 202245****** IQ7+M [0] ---- 0.000 0.195 0.951 1.092 7.227
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.257 1.118 1.147 7.885 0.000 kW
1.232 kWh
0.000 kW
6.162 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.257 1.196 1.301 8.782
09 - 202217****** IQ7+ [0] ---- 0.000 0.257 1.324 1.462 9.460
10 - 202244****** IQ7+M [0] ---- 0.000 0.254 1.287 1.427 9.304
11 - 202224****** IQ7+M [0] ---- 0.000 0.258 1.238 1.363 9.102
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.099 0.447 0.456 3.351 0.000 kW
0.512 kWh
0.000 kW
2.047 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.105 0.513 0.537 3.872
14 - 202216****** IQ7+ [0] ---- 0.000 0.110 0.546 0.579 4.077
15 - 202245****** IQ7+M [0] ---- 0.000 0.109 0.539 0.569 4.005
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.190 kWh
0.000 kW
0.380 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.230 0.380 1.651 27.281
Panel Layout Each Group Production
Last 7 days

Charger History
Voltage PV 0.81 V Voltage Charge 53.07 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.6 °C / 24.7 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-11-09 23:59
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.