Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.075 kW
05/23/2026 17:38 (2187 days) Production Consumption NET Usage
Now 0.152 kW 0.077 kW -0.075 kW
Today 4.635 kWh (0.263 kW) 4.301 kWh (0.244 kW) -0.334 kWh (-0.019 kW)
  - This Week 160.007 kWh (23.756 kWh/day) 153.570 kWh (22.800 kWh/day) -6.437 kWh (-0.956 kWh/day)
  - This Month 561.823 kWh (24.712 kWh/day) 353.292 kWh (15.540 kWh/day) -208.531 kWh (-9.172 kWh/day)
  - This Year 2.515 MWh (17.619 kWh/day) 2.413 MWh (16.905 kWh/day) -0.102 MWh (-0.714 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 161.795 kWh (23.114 kWh/day) 157.711 kWh (22.530 kWh/day) -4.084 kWh (-0.583 kWh/day)
Last 30 Days (04/23/2026) 699.677 kWh (23.323 kWh/day) 419.594 kWh (13.986 kWh/day) -280.083 kWh (-9.336 kWh/day)
Last One Year 6.383 MWh (17.486 kWh/day) 7.785 MWh (21.330 kWh/day) 1.403 MWh (3.843 kWh/day)
Lifetime Since PTO 38.081 MWh (17.406 kW/day) 41.924 MWh (19.163 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.114 MWh 42.504 MWh 4.389 MWh
Voltage/Current 248.6 V / 0.6 A 248.6 V / 0.3 A 248.6 V / -0.3 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/19/2020 23:21 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.167 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.963 1.300 14.778 0.000 kW
1.886 kWh
0.000 kW
11.318 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.898 1.286 14.269
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.891 1.304 14.180
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.900 1.295 14.313
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.750 1.249 12.973
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.915 1.293 14.481
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.758 1.154 12.841 0.000 kW
1.793 kWh
0.000 kW
8.967 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.799 1.186 13.228
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.798 1.179 12.996
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.810 1.205 13.291
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.802 1.214 13.308
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.298 1.983 1.240 15.347 0.000 kW
1.970 kWh
0.000 kW
7.882 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.301 1.940 1.235 14.984
14 - 202216****** IQ7+ [5] VCOP 0.000 0.296 1.994 1.262 15.371
15 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.965 1.245 15.091
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.02 V Current/Power 175.00 A (9.803 kW)
Remain Capacity/Energy 519.6 Ah (26.6 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 90.0 % State Of Health 96.2 %
Run Time 19m to full Report Date 2020-06-19 23:36
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.02 V Cell (MIN/MAX) 3.494 V / 3.506 V (0.012 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 173.2 Ah (8.9 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 90.0 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-19 23:36
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.494 V 3.498 V 3.498 V 3.498 V 3.500 V 3.500 V 3.498 V 3.502 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.502 V 3.502 V 3.503 V 3.499 V 3.504 V 3.501 V 3.503 V 3.506 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -