Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.235 kW
05/23/2026 15:52 (2187 days) Production Consumption NET Usage
Now 0.185 kW -0.050 kW -0.235 kW
Today 4.241 kWh (0.267 kW) 3.573 kWh (0.225 kW) -0.668 kWh (-0.042 kW)
  - This Week 159.613 kWh (23.959 kWh/day) 152.842 kWh (22.942 kWh/day) -6.771 kWh (-1.016 kWh/day)
  - This Month 561.429 kWh (24.775 kWh/day) 352.564 kWh (15.558 kWh/day) -208.865 kWh (-9.217 kWh/day)
  - This Year 2.514 MWh (17.625 kWh/day) 2.412 MWh (16.909 kWh/day) -0.102 MWh (-0.716 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 166.209 kWh (23.744 kWh/day) 157.699 kWh (22.528 kWh/day) -8.510 kWh (-1.216 kWh/day)
Last 30 Days (04/23/2026) 701.847 kWh (23.395 kWh/day) 419.927 kWh (13.998 kWh/day) -281.920 kWh (-9.397 kWh/day)
Last One Year 6.385 MWh (17.494 kWh/day) 7.786 MWh (21.330 kWh/day) 1.400 MWh (3.836 kWh/day)
Lifetime Since PTO 38.080 MWh (17.407 kW/day) 41.923 MWh (19.163 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.114 MWh 42.503 MWh 4.389 MWh
Voltage/Current 249.3 V / 0.7 A 249.3 V / -0.2 A 249.3 V / -0.9 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/13/2020 22:54 (14.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.576 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.232 2.114 9.735 0.000 kW
2.149 kWh
0.000 kW
12.892 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 2.158 2.033 9.457
03 - 202224****** IQ7+M [5] VCOP 0.000 0.298 2.159 2.020 9.489
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.166 2.041 9.520
05 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.999 1.835 8.820
06 - 202245****** IQ7+M [5] VCOP 0.000 0.299 2.178 2.060 9.531
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.954 1.849 8.487 0.000 kW
2.025 kWh
0.000 kW
10.123 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 2.049 1.944 8.749
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.990 1.895 8.640
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 2.059 1.955 8.851
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.070 1.948 8.817
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.289 2.183 2.170 9.882 0.000 kW
2.140 kWh
0.000 kW
8.560 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.296 2.085 2.075 9.695
14 - 202216****** IQ7+ [5] VCOP 0.000 0.292 2.166 2.150 9.933
15 - 202245****** IQ7+M [5] VCOP 0.000 0.285 2.126 2.113 9.799
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.15 V Current/Power 165.98 A (8.821 kW)
Remain Capacity/Energy 445.2 Ah (22.8 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 77.1 % State Of Health 96.2 %
Run Time 47m to full Report Date 2020-07-13 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.15 V Cell (MIN/MAX) 3.316 V / 3.326 V (0.010 V)
Current/Power -0.57 A (-30 W) Runtime 10d 21h 43m to empty
Remain Capacity/Energy 148.4 Ah (7.6 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 77.1 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 23
MOSFET CFET = ON, DFET = ON Reported 2020-07-13 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.316 V 3.317 V 3.318 V 3.318 V 3.319 V 3.320 V 3.320 V 3.321 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.322 V 3.322 V 3.323 V 3.323 V 3.324 V 3.325 V 3.325 V 3.326 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -