Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.354 kW
05/23/2026 16:41 (2187 days) Production Consumption NET Usage
Now 0.308 kW -0.046 kW -0.354 kW
Today 4.429 kWh (0.265 kW) 3.952 kWh (0.237 kW) -0.477 kWh (-0.029 kW)
  - This Week 159.801 kWh (23.865 kWh/day) 153.221 kWh (22.883 kWh/day) -6.580 kWh (-0.983 kWh/day)
  - This Month 561.617 kWh (24.746 kWh/day) 352.943 kWh (15.551 kWh/day) -208.674 kWh (-9.195 kWh/day)
  - This Year 2.515 MWh (17.622 kWh/day) 2.413 MWh (16.908 kWh/day) -0.102 MWh (-0.715 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 163.881 kWh (23.412 kWh/day) 157.900 kWh (22.557 kWh/day) -5.981 kWh (-0.854 kWh/day)
Last 30 Days (04/23/2026) 700.745 kWh (23.358 kWh/day) 419.780 kWh (13.993 kWh/day) -280.965 kWh (-9.365 kWh/day)
Last One Year 6.384 MWh (17.489 kWh/day) 7.786 MWh (21.331 kWh/day) 1.402 MWh (3.841 kWh/day)
Lifetime Since PTO 38.080 MWh (17.407 kW/day) 41.923 MWh (19.163 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.114 MWh 42.503 MWh 4.389 MWh
Voltage/Current 248.9 V / 1.2 A 248.8 V / -0.2 A 248.8 V / -1.4 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/19/2020 22:48 (14.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.016 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.108 2.298 13.430 0.000 kW
2.029 kWh
0.000 kW
12.173 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.299 2.033 2.216 13.069
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.041 2.221 13.118
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 2.064 2.244 13.165
05 - 202244****** IQ7+M [5] VCOP 0.000 0.301 1.876 2.034 12.277
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 2.052 2.230 13.164
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.874 2.033 12.021 0.000 kW
1.925 kWh
0.000 kW
9.625 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.940 2.103 12.582
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.903 2.051 12.254
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.956 2.104 12.658
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.952 2.108 12.673
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.281 2.086 2.088 12.776 0.000 kW
2.054 kWh
0.000 kW
8.218 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.279 2.012 2.012 12.283
14 - 202216****** IQ7+ [5] VCOP 0.000 0.280 2.075 2.092 12.765
15 - 202245****** IQ7+M [5] VCOP 0.000 0.277 2.045 2.053 12.553
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.34 V Current/Power 163.42 A (8.553 kW)
Remain Capacity/Energy 205.5 Ah (10.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 35.6 % State Of Health 96.2 %
Run Time 2h 16m to full Report Date 2020-07-19 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.34 V Cell (MIN/MAX) 3.265 V / 3.277 V (0.012 V)
Current/Power -0.58 A (-30 W) Runtime 4d 21h 17m to empty
Remain Capacity/Energy 68.5 Ah (3.5 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 35.6 % State Of Health 96.2 %
Temperature 26.0 °C Cycle 23
MOSFET CFET = ON, DFET = ON Reported 2020-07-19 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.265 V 3.266 V 3.267 V 3.267 V 3.271 V 3.268 V 3.269 V 3.271 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.272 V 3.270 V 3.274 V 3.272 V 3.275 V 3.274 V 3.276 V 3.277 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -