Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.350 kW
05/23/2026 16:47 (2187 days) Production Consumption NET Usage
Now 0.297 kW -0.053 kW -0.350 kW
Today 4.463 kWh (0.266 kW) 3.954 kWh (0.235 kW) -0.509 kWh (-0.030 kW)
  - This Week 159.835 kWh (23.854 kWh/day) 153.223 kWh (22.867 kWh/day) -6.612 kWh (-0.987 kWh/day)
  - This Month 561.651 kWh (24.742 kWh/day) 352.945 kWh (15.548 kWh/day) -208.706 kWh (-9.194 kWh/day)
  - This Year 2.515 MWh (17.622 kWh/day) 2.413 MWh (16.907 kWh/day) -0.102 MWh (-0.715 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 163.585 kWh (23.369 kWh/day) 157.872 kWh (22.553 kWh/day) -5.713 kWh (-0.816 kWh/day)
Last 30 Days (04/23/2026) 700.637 kWh (23.355 kWh/day) 419.742 kWh (13.991 kWh/day) -280.895 kWh (-9.363 kWh/day)
Last One Year 6.383 MWh (17.489 kWh/day) 7.786 MWh (21.331 kWh/day) 1.402 MWh (3.842 kWh/day)
Lifetime Since PTO 38.080 MWh (17.407 kW/day) 41.923 MWh (19.163 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.114 MWh 42.503 MWh 4.389 MWh
Voltage/Current 248.8 V / 1.2 A 248.7 V / -0.2 A 248.7 V / -1.4 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/20/2020 23:28 (14.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.590 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.298 2.102 2.108 13.424 0.000 kW
2.044 kWh
0.000 kW
12.261 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.050 2.033 13.069
03 - 202224****** IQ7+M [5] VCOP 0.000 0.299 2.066 2.041 13.138
04 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.056 2.064 13.187
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.930 1.876 12.318
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 2.057 2.052 13.156
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.867 1.874 12.046 0.000 kW
1.932 kWh
0.000 kW
9.662 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.954 1.940 12.578
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 1.898 1.903 12.263
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.967 1.956 12.659
11 - 202224****** IQ7+M [5] VCOP 0.000 0.300 1.976 1.952 12.677
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.281 1.948 2.086 12.692 0.000 kW
1.917 kWh
0.000 kW
7.667 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.286 1.873 2.012 12.221
14 - 202216****** IQ7+ [5] VCOP 0.000 0.284 1.942 2.075 12.690
15 - 202245****** IQ7+M [5] VCOP 0.000 0.279 1.905 2.045 12.485
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 51.94 V Current/Power 162.15 A (8.422 kW)
Remain Capacity/Energy 165.0 Ah (8.4 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 28.6 % State Of Health 96.2 %
Run Time 2h 32m to full Report Date 2020-07-20 23:49
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 51.94 V Cell (MIN/MAX) 3.240 V / 3.252 V (0.012 V)
Current/Power -0.57 A (-29 W) Runtime 4d 0h 39m to empty
Remain Capacity/Energy 55.0 Ah (2.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 28.6 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 23
MOSFET CFET = ON, DFET = ON Reported 2020-07-20 23:49
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.240 V 3.240 V 3.242 V 3.241 V 3.246 V 3.243 V 3.246 V 3.246 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.245 V 3.245 V 3.248 V 3.246 V 3.249 V 3.250 V 3.251 V 3.252 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -