Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.350 kW
05/23/2026 16:47 (2187 days) Production Consumption NET Usage
Now 0.297 kW -0.053 kW -0.350 kW
Today 4.463 kWh (0.266 kW) 3.954 kWh (0.235 kW) -0.509 kWh (-0.030 kW)
  - This Week 159.835 kWh (23.854 kWh/day) 153.223 kWh (22.867 kWh/day) -6.612 kWh (-0.987 kWh/day)
  - This Month 561.651 kWh (24.742 kWh/day) 352.945 kWh (15.548 kWh/day) -208.706 kWh (-9.194 kWh/day)
  - This Year 2.515 MWh (17.622 kWh/day) 2.413 MWh (16.907 kWh/day) -0.102 MWh (-0.715 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 163.585 kWh (23.369 kWh/day) 157.872 kWh (22.553 kWh/day) -5.713 kWh (-0.816 kWh/day)
Last 30 Days (04/23/2026) 700.637 kWh (23.355 kWh/day) 419.742 kWh (13.991 kWh/day) -280.895 kWh (-9.363 kWh/day)
Last One Year 6.383 MWh (17.489 kWh/day) 7.786 MWh (21.331 kWh/day) 1.402 MWh (3.842 kWh/day)
Lifetime Since PTO 38.080 MWh (17.407 kW/day) 41.923 MWh (19.163 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.114 MWh 42.503 MWh 4.389 MWh
Voltage/Current 248.8 V / 1.2 A 248.7 V / -0.2 A 248.7 V / -1.4 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/07/2020 23:25 (12.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.646 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.288 1.159 1.128 10.348 0.000 kW
1.137 kWh
0.000 kW
6.821 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.146 1.112 10.077
03 - 202224****** IQ7+M [5] VCOP 0.000 0.286 1.162 1.131 10.228
04 - 202232****** IQ7+ [5] VCOP 0.000 0.287 1.156 1.121 10.276
05 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.057 1.100 9.703
06 - 202245****** IQ7+M [5] VCOP 0.000 0.292 1.140 1.107 10.095
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.289 1.029 1.089 9.668 0.000 kW
1.030 kWh
0.000 kW
5.151 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.285 1.015 1.093 9.999
09 - 202217****** IQ7+ [5] VCOP 0.000 0.284 1.034 1.099 9.769
10 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.041 1.107 10.074
11 - 202224****** IQ7+M [5] VCOP 0.000 0.284 1.032 1.098 10.059
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.291 1.165 1.025 9.381 0.000 kW
1.168 kWh
0.000 kW
4.674 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.287 1.165 1.019 8.970
14 - 202216****** IQ7+ [5] VCOP 0.000 0.288 1.178 1.043 9.432
15 - 202245****** IQ7+M [5] VCOP 0.000 0.288 1.166 1.028 9.280
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.60 V Current/Power 180.00 A (10.368 kW)
Remain Capacity/Energy 572.4 Ah (29.3 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.2 % State Of Health 96.2 %
Run Time 1m to full Report Date 2020-08-07 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.60 V Cell (MIN/MAX) 3.587 V / 3.606 V (0.019 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 190.8 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.2 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-07 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.600 V 3.597 V 3.597 V 3.599 V 3.601 V 3.602 V 3.600 V 3.602 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.601 V 3.600 V 3.596 V 3.602 V 3.602 V 3.601 V 3.587 V 3.606 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -