Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.055 kW
04/08/2026 01:16 (2142 days) Production Consumption NET Usage
Now 0.317 kW 0.372 kW 0.055 kW
Today 0.404 kWh (0.317 kW) 0.763 kWh (0.598 kW) 0.359 kWh (0.281 kW)
  - This Week 71.927 kWh (23.559 kWh/day) 36.325 kWh (11.898 kWh/day) -35.602 kWh (-11.661 kWh/day)
  - This Month 124.532 kWh (17.656 kWh/day) 97.384 kWh (13.807 kWh/day) -27.148 kWh (-3.849 kWh/day)
  - This Year 1.354 MWh (13.951 kWh/day) 1.663 MWh (17.132 kWh/day) 0.309 MWh (3.182 kWh/day)
Yesterday 35.605 kWh (1.484 kW) 10.861 kWh (0.453 kW) -24.744 kWh (-1.031 kW)
Last 7 Days 124.532 kWh (17.790 kWh/day) 96.819 kWh (13.831 kWh/day) -27.713 kWh (-3.959 kWh/day)
Last 30 Days (03/09/2026) 615.595 kWh (20.520 kWh/day) 443.274 kWh (14.776 kWh/day) -172.321 kWh (-5.744 kWh/day)
Last One Year 6.161 MWh (16.879 kWh/day) 7.828 MWh (21.445 kWh/day) 1.667 MWh (4.567 kWh/day)
Lifetime Since PTO 36.920 MWh (17.236 kW/day) 41.173 MWh (19.222 kW/day) 4.254 MWh (1.986 kW/day)
Lifetime Since Install 36.954 MWh 41.753 MWh 4.800 MWh
Voltage/Current 251.3 V / 1.3 A 251.2 V / 1.5 A 251.2 V / 0.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/10/2020 22:25 (13.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.424 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.085 0.309 2.189 11.796 0.000 kW
0.305 kWh
0.000 kW
1.827 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.085 0.303 2.159 11.535
03 - 202224****** IQ7+M [0] ---- 0.000 0.085 0.311 2.189 11.615
04 - 202232****** IQ7+ [0] ---- 0.000 0.085 0.304 2.193 11.620
05 - 202244****** IQ7+M [0] ---- 0.000 0.081 0.298 2.093 10.964
06 - 202245****** IQ7+M [0] ---- 0.000 0.082 0.303 2.164 11.579
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.073 0.271 1.982 10.489 0.000 kW
0.273 kWh
0.000 kW
1.364 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.074 0.270 2.079 10.814
09 - 202217****** IQ7+ [0] ---- 0.000 0.075 0.274 2.023 10.663
10 - 202244****** IQ7+M [0] ---- 0.000 0.074 0.276 2.092 10.901
11 - 202224****** IQ7+M [0] ---- 0.000 0.075 0.273 2.101 10.874
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.085 0.304 1.985 11.267 0.000 kW
0.308 kWh
0.000 kW
1.232 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.086 0.307 1.905 11.042
14 - 202216****** IQ7+ [0] ---- 0.000 0.086 0.313 1.998 11.349
15 - 202245****** IQ7+M [0] ---- 0.000 0.085 0.308 1.969 11.178
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.25 V Current/Power 166.29 A (8.855 kW)
Remain Capacity/Energy 566.7 Ah (29.0 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 98.2 % State Of Health 96.2 %
Run Time 3m to full Report Date 2020-07-10 23:40
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.