Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.234 kW
05/23/2026 15:11 (2187 days) Production Consumption NET Usage
Now 0.181 kW -0.053 kW -0.234 kW
Today 4.082 kWh (0.268 kW) 3.368 kWh (0.221 kW) -0.714 kWh (-0.047 kW)
  - This Week 159.454 kWh (24.036 kWh/day) 152.637 kWh (23.009 kWh/day) -6.817 kWh (-1.028 kWh/day)
  - This Month 561.270 kWh (24.798 kWh/day) 352.359 kWh (15.568 kWh/day) -208.911 kWh (-9.230 kWh/day)
  - This Year 2.514 MWh (17.628 kWh/day) 2.412 MWh (16.911 kWh/day) -0.102 MWh (-0.717 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 168.483 kWh (24.069 kWh/day) 157.637 kWh (22.520 kWh/day) -10.846 kWh (-1.549 kWh/day)
Last 30 Days (04/23/2026) 703.699 kWh (23.457 kWh/day) 419.944 kWh (13.998 kWh/day) -283.755 kWh (-9.458 kWh/day)
Last One Year 6.387 MWh (17.499 kWh/day) 7.786 MWh (21.331 kWh/day) 1.399 MWh (3.832 kWh/day)
Lifetime Since PTO 38.080 MWh (17.407 kW/day) 41.923 MWh (19.164 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.114 MWh 42.503 MWh 4.389 MWh
Voltage/Current 248.9 V / 0.7 A 249.1 V / -0.2 A 249.0 V / -0.9 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/27/2020 23:24 (12.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 24.654 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.278 1.745 1.814 12.786 0.000 kW
1.728 kWh
0.000 kW
10.371 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.277 1.721 1.784 12.556
03 - 202224****** IQ7+M [5] VCOP 0.000 0.276 1.744 1.823 12.809
04 - 202232****** IQ7+ [5] VCOP 0.000 0.277 1.732 1.839 12.874
05 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.711 1.697 12.027
06 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.718 1.734 12.323
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 1.743 1.726 12.318 0.000 kW
1.761 kWh
0.000 kW
8.805 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.764 1.686 12.302
09 - 202217****** IQ7+ [5] VCOP 0.000 0.293 1.743 1.725 12.314
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.782 1.756 12.575
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.773 1.752 12.602
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.233 1.385 1.742 11.501 0.000 kW
1.369 kWh
0.000 kW
5.477 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.231 1.339 1.715 11.135
14 - 202216****** IQ7+ [5] VCOP 0.000 0.234 1.388 1.737 11.506
15 - 202245****** IQ7+M [5] VCOP 0.000 0.232 1.365 1.708 11.319
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 48.37 V Current/Power 151.02 A (7.304 kW)
Remain Capacity/Energy 31.2 Ah (1.6 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 5.3 % State Of Health 98.5 %
Run Time 3h 42m to full Report Date 2020-08-27 23:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 48.37 V Cell (MIN/MAX) 3.016 V / 3.030 V (0.014 V)
Current/Power -0.55 A (-26 W) Runtime 18h 54m to empty
Remain Capacity/Energy 10.4 Ah (0.5 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 5.3 % State Of Health 98.5 %
Temperature 25.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-27 23:52
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.016 V 3.016 V 3.017 V 3.017 V 3.026 V 3.018 V 3.027 V 3.028 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.016 V 3.023 V 3.023 V 3.027 V 3.019 V 3.028 V 3.029 V 3.030 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -