Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.279 kW
04/07/2026 23:34 (2141 days) Production Consumption NET Usage
Now 0.316 kW 0.595 kW 0.279 kW
Today 35.472 kWh (1.505 kW) 10.625 kWh (0.451 kW) -24.847 kWh (-1.054 kW)
  - This Week 71.390 kWh (23.938 kWh/day) 35.326 kWh (11.845 kWh/day) -36.064 kWh (-12.093 kWh/day)
  - This Month 123.995 kWh (17.758 kWh/day) 96.385 kWh (13.804 kWh/day) -27.610 kWh (-3.954 kWh/day)
  - This Year 1.353 MWh (13.955 kWh/day) 1.662 MWh (17.134 kWh/day) 0.308 MWh (3.179 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 123.995 kWh (17.714 kWh/day) 96.543 kWh (13.792 kWh/day) -27.452 kWh (-3.922 kWh/day)
Last 30 Days (03/08/2026) 615.058 kWh (20.502 kWh/day) 443.278 kWh (14.776 kWh/day) -171.780 kWh (-5.726 kWh/day)
Last One Year 6.160 MWh (16.877 kWh/day) 7.828 MWh (21.446 kWh/day) 1.668 MWh (4.569 kWh/day)
Lifetime Since PTO 36.919 MWh (17.236 kW/day) 41.172 MWh (19.222 kW/day) 4.253 MWh (1.986 kW/day)
Lifetime Since Install 36.953 MWh 41.752 MWh 4.799 MWh
Voltage/Current 250.4 V / 1.3 A 250.4 V / 2.4 A 250.4 V / 1.1 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/12/2020 21:15 (13.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.257 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.547 1.767 11.257 0.000 kW
1.499 kWh
0.000 kW
8.991 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.498 1.739 11.000
03 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.531 1.772 11.194
04 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.543 1.769 11.216
05 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.390 1.640 10.442
06 - 202245****** IQ7+M [0] ---- 0.000 0.295 1.483 1.733 10.952
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.299 1.364 1.675 10.488 0.000 kW
1.390 kWh
0.000 kW
6.949 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.299 1.384 1.722 10.643
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.369 1.686 10.555
10 - 202244****** IQ7+M [0] ---- 0.000 0.298 1.417 1.744 10.782
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.416 1.747 10.780
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.264 1.587 1.579 10.440 0.000 kW
1.579 kWh
0.000 kW
6.317 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.265 1.575 1.507 10.126
14 - 202216****** IQ7+ [0] ---- 0.000 0.268 1.590 1.591 10.497
15 - 202245****** IQ7+M [0] ---- 0.000 0.261 1.565 1.568 10.343
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.60 V Current/Power 179.97 A (10.367 kW)
Remain Capacity/Energy 568.8 Ah (29.1 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 98.5 % State Of Health 96.2 %
Run Time 2m to full Report Date 2020-08-12 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.