Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.748 kW
04/07/2026 22:02 (2141 days) Production Consumption NET Usage
Now 0.317 kW -0.431 kW -0.748 kW
Today 34.988 kWh (1.587 kW) 10.148 kWh (0.460 kW) -24.840 kWh (-1.127 kW)
  - This Week 70.906 kWh (24.294 kWh/day) 34.849 kWh (11.940 kWh/day) -36.057 kWh (-12.354 kWh/day)
  - This Month 123.511 kWh (17.852 kWh/day) 95.908 kWh (13.862 kWh/day) -27.603 kWh (-3.990 kWh/day)
  - This Year 1.353 MWh (13.959 kWh/day) 1.661 MWh (17.141 kWh/day) 0.308 MWh (3.181 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 123.511 kWh (17.644 kWh/day) 96.908 kWh (13.844 kWh/day) -26.603 kWh (-3.800 kWh/day)
Last 30 Days (03/08/2026) 614.574 kWh (20.486 kWh/day) 443.330 kWh (14.778 kWh/day) -171.244 kWh (-5.708 kWh/day)
Last One Year 6.160 MWh (16.876 kWh/day) 7.828 MWh (21.447 kWh/day) 1.668 MWh (4.571 kWh/day)
Lifetime Since PTO 36.919 MWh (17.236 kW/day) 41.172 MWh (19.222 kW/day) 4.253 MWh (1.986 kW/day)
Lifetime Since Install 36.953 MWh 41.752 MWh 4.799 MWh
Voltage/Current 250.2 V / 1.3 A 250.2 V / -1.7 A 250.2 V / -3.0 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/25/2020 23:53 (13.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.594 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.288 1.655 1.767 12.199 0.000 kW
1.616 kWh
0.000 kW
9.698 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.291 1.620 1.732 11.980
03 - 202224****** IQ7+M [0] ---- 0.000 0.284 1.652 1.769 12.215
04 - 202232****** IQ7+ [0] ---- 0.000 0.285 1.647 1.790 12.277
05 - 202244****** IQ7+M [0] ---- 0.000 0.291 1.543 1.642 11.507
06 - 202245****** IQ7+M [0] ---- 0.000 0.288 1.582 1.681 11.801
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 1.583 1.693 11.748 0.000 kW
1.593 kWh
0.000 kW
7.967 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.561 1.640 11.874
09 - 202217****** IQ7+ [0] ---- 0.000 0.293 1.594 1.694 11.731
10 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.614 1.699 12.049
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.615 1.694 12.098
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.226 1.496 1.680 10.813 0.000 kW
1.482 kWh
0.000 kW
5.928 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.224 1.469 1.635 10.354
14 - 202216****** IQ7+ [0] ---- 0.000 0.225 1.494 1.678 10.827
15 - 202245****** IQ7+M [0] ---- 0.000 0.221 1.469 1.652 10.648
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 51.36 V Current/Power 160.34 A (8.235 kW)
Remain Capacity/Energy 97.9 Ah (5.0 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 17.0 % State Of Health 96.2 %
Run Time 2h 59m to full Report Date 2020-08-25 23:39
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 51.36 V Cell (MIN/MAX) 3.202 V / 3.216 V (0.014 V)
Current/Power -0.55 A (-28 W) Runtime 2d 11h 12m to empty
Remain Capacity/Energy 32.6 Ah (1.7 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 17.0 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-25 23:39
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.202 V 3.203 V 3.205 V 3.205 V 3.210 V 3.206 V 3.212 V 3.211 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.209 V 3.209 V 3.212 V 3.210 V 3.212 V 3.214 V 3.215 V 3.216 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -