Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.729 kW
04/07/2026 22:00 (2141 days) Production Consumption NET Usage
Now 0.316 kW -0.413 kW -0.729 kW
Today 34.977 kWh (1.589 kW) 10.163 kWh (0.462 kW) -24.814 kWh (-1.127 kW)
  - This Week 70.895 kWh (24.303 kWh/day) 34.864 kWh (11.951 kWh/day) -36.031 kWh (-12.351 kWh/day)
  - This Month 123.500 kWh (17.854 kWh/day) 95.923 kWh (13.867 kWh/day) -27.577 kWh (-3.987 kWh/day)
  - This Year 1.353 MWh (13.959 kWh/day) 1.661 MWh (17.141 kWh/day) 0.308 MWh (3.182 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 123.500 kWh (17.643 kWh/day) 96.938 kWh (13.848 kWh/day) -26.562 kWh (-3.795 kWh/day)
Last 30 Days (03/08/2026) 614.563 kWh (20.485 kWh/day) 443.356 kWh (14.779 kWh/day) -171.207 kWh (-5.707 kWh/day)
Last One Year 6.160 MWh (16.876 kWh/day) 7.828 MWh (21.447 kWh/day) 1.668 MWh (4.571 kWh/day)
Lifetime Since PTO 36.919 MWh (17.236 kW/day) 41.172 MWh (19.222 kW/day) 4.253 MWh (1.986 kW/day)
Lifetime Since Install 36.953 MWh 41.752 MWh 4.799 MWh
Voltage/Current 249.9 V / 1.3 A 250.1 V / -1.7 A 250.0 V / -2.9 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/29/2020 23:38 (12.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.211 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.284 0.721 1.603 12.063 0.000 kW
0.716 kWh
0.000 kW
4.298 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.281 0.713 1.577 11.866
03 - 202224****** IQ7+M [0] ---- 0.000 0.287 0.727 1.609 12.088
04 - 202232****** IQ7+ [0] ---- 0.000 0.281 0.717 1.616 12.119
05 - 202244****** IQ7+M [0] ---- 0.000 0.283 0.708 1.507 11.455
06 - 202245****** IQ7+M [0] ---- 0.000 0.284 0.711 1.530 11.662
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.287 0.709 1.538 11.697 0.000 kW
0.726 kWh
0.000 kW
3.630 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.290 0.736 1.507 11.629
09 - 202217****** IQ7+ [0] ---- 0.000 0.291 0.702 1.537 11.704
10 - 202244****** IQ7+M [0] ---- 0.000 0.291 0.744 1.555 11.907
11 - 202224****** IQ7+M [0] ---- 0.000 0.290 0.739 1.547 11.896
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.230 0.572 1.476 10.698 0.000 kW
0.571 kWh
0.000 kW
2.283 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.235 0.555 1.456 10.434
14 - 202216****** IQ7+ [0] ---- 0.000 0.231 0.583 1.475 10.710
15 - 202245****** IQ7+M [0] ---- 0.000 0.225 0.573 1.449 10.540
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.61 V Current/Power 179.89 A (10.363 kW)
Remain Capacity/Energy 591.0 Ah (30.3 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 100.0 % State Of Health 98.5 %
Run Time - to full Report Date 2020-08-29 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.61 V Cell (MIN/MAX) 3.587 V / 3.606 V (0.019 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 197.0 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 100.0 % State Of Health 98.5 %
Temperature 25.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-08-29 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.599 V 3.600 V 3.598 V 3.600 V 3.600 V 3.587 V 3.601 V 3.604 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.601 V 3.598 V 3.600 V 3.594 V 3.605 V 3.606 V 3.604 V 3.604 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -