Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.524 kW
04/07/2026 20:17 (2141 days) Production Consumption NET Usage
Now 0.317 kW 0.841 kW 0.524 kW
Today 34.431 kWh (1.697 kW) 12.150 kWh (0.599 kW) -22.281 kWh (-1.098 kW)
  - This Week 70.349 kWh (24.725 kWh/day) 36.851 kWh (12.951 kWh/day) -33.498 kWh (-11.773 kWh/day)
  - This Month 122.954 kWh (17.962 kWh/day) 97.910 kWh (14.303 kWh/day) -25.044 kWh (-3.659 kWh/day)
  - This Year 1.352 MWh (13.964 kWh/day) 1.663 MWh (17.174 kWh/day) 0.311 MWh (3.210 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 122.954 kWh (17.565 kWh/day) 99.707 kWh (14.244 kWh/day) -23.247 kWh (-3.321 kWh/day)
Last 30 Days (03/08/2026) 614.017 kWh (20.467 kWh/day) 446.679 kWh (14.889 kWh/day) -167.338 kWh (-5.578 kWh/day)
Last One Year 6.159 MWh (16.874 kWh/day) 7.832 MWh (21.456 kWh/day) 1.672 MWh (4.582 kWh/day)
Lifetime Since PTO 36.918 MWh (17.237 kW/day) 41.174 MWh (19.224 kW/day) 4.256 MWh (1.987 kW/day)
Lifetime Since Install 36.952 MWh 41.754 MWh 4.802 MWh
Voltage/Current 249.2 V / 1.3 A 249.2 V / 3.4 A 249.2 V / 2.1 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/04/2020 23:40 (12.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.882 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.964 1.419 8.024 0.000 kW
1.932 kWh
0.000 kW
11.591 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.934 1.400 7.926
03 - 202224****** IQ7+M [0] ---- 0.000 0.295 1.964 1.414 8.065
04 - 202232****** IQ7+ [0] ---- 0.000 0.294 1.955 1.407 8.040
05 - 202244****** IQ7+M [0] ---- 0.000 0.295 1.890 1.379 7.758
06 - 202245****** IQ7+M [0] ---- 0.000 0.292 1.884 1.393 7.836
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.298 1.989 1.385 7.746 0.000 kW
2.000 kWh
0.000 kW
10.000 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.298 1.979 1.366 7.778
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.968 1.386 7.730
10 - 202244****** IQ7+M [0] ---- 0.000 0.298 2.030 1.394 7.923
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 2.034 1.385 7.902
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.235 1.599 1.225 7.097 0.000 kW
1.573 kWh
0.000 kW
6.291 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.233 1.531 1.222 6.985
14 - 202216****** IQ7+ [0] ---- 0.000 0.235 1.597 1.230 7.157
15 - 202245****** IQ7+M [0] ---- 0.000 0.229 1.564 1.209 7.041
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.