Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.515 kW
12/21/2025 14:03 (2034 days) Production Consumption NET Usage
Now 2.155 kW 0.640 kW -1.515 kW
Today 8.227 kWh (0.584 kW) 7.080 kWh (0.503 kW) -1.147 kWh (-0.081 kW)
  - This Week 8.227 kWh (14.026 kWh/day) 7.080 kWh (12.071 kWh/day) -1.147 kWh (-1.955 kWh/day)
  - This Month 183.133 kWh (8.896 kWh/day) 430.361 kWh (20.905 kWh/day) 247.228 kWh (12.009 kWh/day)
  - This Year 6.052 MWh (17.068 kWh/day) 7.347 MWh (20.719 kWh/day) 1.295 MWh (3.651 kWh/day)
Yesterday 12.220 kWh (0.509 kW) 17.015 kWh (0.709 kW) 4.795 kWh (0.200 kW)
Last 7 Days 54.155 kWh (7.736 kWh/day) 162.008 kWh (23.142 kWh/day) 107.853 kWh (15.406 kWh/day)
Last 30 Days 254.381 kWh (8.479 kWh/day) 620.587 kWh (20.686 kWh/day) 366.206 kWh (12.207 kWh/day)
Last One Year 6.114 MWh (16.749 kWh/day) 7.595 MWh (20.809 kWh/day) 1.482 MWh (4.059 kWh/day)
Lifetime Since PTO 35.503 MWh (17.449 kW/day) 39.299 MWh (19.315 kW/day) 3.796 MWh (1.866 kW/day)
Lifetime Since Install 35.537 MWh 39.879 MWh 4.342 MWh
Voltage/Current 252.3 V / 8.5 A 252.2 V / 2.5 A 252.3 V / -6.0 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/30/2020 19:15 (14.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 32.596 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.292 1.052 2.620 0.000 kW
2.219 kWh
0.000 kW
13.315 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 2.234 1.038 2.583
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.236 1.061 2.634
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.243 1.050 2.611
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.069 1.032 2.576
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.241 1.039 2.592
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 2.068 0.982 2.420 0.000 kW
2.107 kWh
0.000 kW
10.537 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 2.123 0.999 2.515
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 2.108 1.005 2.492
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 2.122 1.017 2.555
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.115 1.009 2.551
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.290 2.221 0.950 2.301 0.000 kW
2.186 kWh
0.000 kW
8.745 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.290 2.154 0.929 2.243
14 - 202216****** IQ7+ [5] VCOP 0.000 0.289 2.202 0.963 2.335
15 - 202245****** IQ7+M [5] VCOP 0.000 0.282 2.168 0.953 2.315
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.03 V Current/Power 175.16 A (9.815 kW)
Remain Capacity/Energy 574.8 Ah (29.4 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.6 % State Of Health 96.2 %
Run Time - to full Report Date 2020-05-30 23:13
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.03 V Cell (MIN/MAX) 3.494 V / 3.506 V (0.012 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 191.6 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.6 % State Of Health 96.2 %
Temperature 24.0 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-05-30 23:13
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.494 V 3.500 V 3.496 V 3.503 V 3.502 V 3.505 V 3.501 V 3.505 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.502 V 3.503 V 3.501 V 3.501 V 3.506 V 3.500 V 3.505 V 3.504 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -