Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.572 kW
04/07/2026 20:18 (2141 days) Production Consumption NET Usage
Now 0.316 kW -1.256 kW -1.572 kW
Today 34.436 kWh (1.696 kW) 12.160 kWh (0.599 kW) -22.276 kWh (-1.097 kW)
  - This Week 70.354 kWh (24.720 kWh/day) 36.861 kWh (12.952 kWh/day) -33.493 kWh (-11.768 kWh/day)
  - This Month 122.959 kWh (17.960 kWh/day) 97.920 kWh (14.303 kWh/day) -25.039 kWh (-3.657 kWh/day)
  - This Year 1.352 MWh (13.964 kWh/day) 1.663 MWh (17.174 kWh/day) 0.311 MWh (3.210 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 122.959 kWh (17.566 kWh/day) 99.717 kWh (14.245 kWh/day) -23.242 kWh (-3.320 kWh/day)
Last 30 Days (03/08/2026) 614.022 kWh (20.467 kWh/day) 446.680 kWh (14.889 kWh/day) -167.342 kWh (-5.578 kWh/day)
Last One Year 6.159 MWh (16.874 kWh/day) 7.832 MWh (21.456 kWh/day) 1.672 MWh (4.582 kWh/day)
Lifetime Since PTO 36.918 MWh (17.237 kW/day) 41.174 MWh (19.224 kW/day) 4.256 MWh (1.987 kW/day)
Lifetime Since Install 36.952 MWh 41.754 MWh 4.802 MWh
Voltage/Current 250.1 V / 1.3 A 250.0 V / -5.0 A 250.0 V / -6.3 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/21/2020 23:04 (12.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.971 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.269 1.826 1.820 10.893 0.000 kW
1.808 kWh
0.000 kW
10.850 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.266 1.813 1.810 10.793
03 - 202224****** IQ7+M [0] ---- 0.000 0.270 1.841 1.839 10.961
04 - 202232****** IQ7+ [0] ---- 0.000 0.268 1.832 1.834 10.892
05 - 202244****** IQ7+M [0] ---- 0.000 0.267 1.776 1.760 10.612
06 - 202245****** IQ7+M [0] ---- 0.000 0.263 1.761 1.744 10.599
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 1.921 1.890 11.150 0.000 kW
1.906 kWh
0.000 kW
9.529 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.800 1.799 10.715
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.928 1.895 11.210
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.946 1.920 11.319
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.935 1.912 11.245
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.204 1.409 1.414 8.843 0.000 kW
1.398 kWh
0.000 kW
5.592 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.205 1.377 1.371 8.694
14 - 202216****** IQ7+ [0] ---- 0.000 0.206 1.415 1.423 8.895
15 - 202245****** IQ7+M [0] ---- 0.000 0.201 1.391 1.400 8.755
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.62 V Current/Power 179.79 A (10.359 kW)
Remain Capacity/Energy 574.8 Ah (29.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 97.3 % State Of Health 98.5 %
Run Time 5m to full Report Date 2020-09-21 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.