Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.720 kW
12/21/2025 13:59 (2034 days) Production Consumption NET Usage
Now 2.152 kW 0.432 kW -1.720 kW
Today 8.066 kWh (0.576 kW) 7.043 kWh (0.503 kW) -1.023 kWh (-0.073 kW)
  - This Week 8.066 kWh (13.822 kWh/day) 7.043 kWh (12.069 kWh/day) -1.023 kWh (-1.753 kWh/day)
  - This Month 182.972 kWh (8.889 kWh/day) 430.324 kWh (20.906 kWh/day) 247.352 kWh (12.017 kWh/day)
  - This Year 6.052 MWh (17.068 kWh/day) 7.347 MWh (20.719 kWh/day) 1.295 MWh (3.651 kWh/day)
Yesterday 12.220 kWh (0.509 kW) 17.015 kWh (0.709 kW) 4.795 kWh (0.200 kW)
Last 7 Days 54.155 kWh (7.736 kWh/day) 162.008 kWh (23.142 kWh/day) 107.853 kWh (15.406 kWh/day)
Last 30 Days 254.381 kWh (8.479 kWh/day) 620.587 kWh (20.686 kWh/day) 366.206 kWh (12.207 kWh/day)
Last One Year 6.114 MWh (16.749 kWh/day) 7.595 MWh (20.809 kWh/day) 1.482 MWh (4.059 kWh/day)
Lifetime Since PTO 35.503 MWh (17.449 kW/day) 39.299 MWh (19.315 kW/day) 3.797 MWh (1.866 kW/day)
Lifetime Since Install 35.537 MWh 39.879 MWh 4.343 MWh
Voltage/Current 252.2 V / 8.5 A 252.0 V / 1.7 A 252.1 V / -6.8 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/07/2020 23:31 (14.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.240 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.105 1.854 11.520 0.000 kW
2.004 kWh
0.000 kW
12.026 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 2.029 1.785 11.138
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.003 1.784 11.120
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.027 1.786 11.159
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.803 1.634 10.290
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.059 1.811 11.176
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.838 1.524 9.992 0.000 kW
1.868 kWh
0.000 kW
9.341 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.873 1.629 10.326
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.857 1.581 10.240
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.882 1.659 10.465
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.891 1.666 10.464
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.287 2.242 1.850 11.809 0.000 kW
2.218 kWh
0.000 kW
8.873 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.286 2.194 1.795 11.525
14 - 202216****** IQ7+ [5] VCOP 0.000 0.286 2.241 1.848 11.779
15 - 202245****** IQ7+M [5] VCOP 0.000 0.284 2.196 1.818 11.596
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.03 V Current/Power 175.10 A (9.811 kW)
Remain Capacity/Energy 569.4 Ah (29.2 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 98.6 % State Of Health 96.2 %
Run Time 2m to full Report Date 2020-06-07 23:18
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.03 V Cell (MIN/MAX) 3.495 V / 3.506 V (0.011 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 189.8 Ah (9.7 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 98.6 % State Of Health 96.2 %
Temperature 24.5 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-07 23:18
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.501 V 3.495 V 3.503 V 3.500 V 3.500 V 3.505 V 3.506 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.502 V 3.500 V 3.501 V 3.499 V 3.503 V 3.506 V 3.506 V 3.504 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -