Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.935 kW
12/21/2025 14:14 (2034 days) Production Consumption NET Usage
Now 2.423 kW 0.488 kW -1.935 kW
Today 8.602 kWh (0.604 kW) 7.174 kWh (0.504 kW) -1.428 kWh (-0.100 kW)
  - This Week 8.602 kWh (14.490 kWh/day) 7.174 kWh (12.085 kWh/day) -1.428 kWh (-2.405 kWh/day)
  - This Month 183.508 kWh (8.911 kWh/day) 430.455 kWh (20.902 kWh/day) 246.947 kWh (11.991 kWh/day)
  - This Year 6.052 MWh (17.069 kWh/day) 7.347 MWh (20.719 kWh/day) 1.294 MWh (3.650 kWh/day)
Yesterday 12.220 kWh (0.509 kW) 17.015 kWh (0.709 kW) 4.795 kWh (0.200 kW)
Last 7 Days 54.155 kWh (7.736 kWh/day) 162.008 kWh (23.142 kWh/day) 107.853 kWh (15.406 kWh/day)
Last 30 Days 254.381 kWh (8.479 kWh/day) 620.587 kWh (20.686 kWh/day) 366.206 kWh (12.207 kWh/day)
Last One Year 6.114 MWh (16.749 kWh/day) 7.595 MWh (20.809 kWh/day) 1.482 MWh (4.059 kWh/day)
Lifetime Since PTO 35.503 MWh (17.450 kW/day) 39.300 MWh (19.315 kW/day) 3.796 MWh (1.866 kW/day)
Lifetime Since Install 35.537 MWh 39.879 MWh 4.342 MWh
Voltage/Current 252.4 V / 9.6 A 252.4 V / 1.9 A 252.4 V / -7.7 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/10/2020 23:35 (15.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.501 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.285 2.203 2.357 12.660 0.000 kW
2.146 kWh
0.000 kW
12.874 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.282 2.152 2.262 12.186
03 - 202224****** IQ7+M [5] VCOP 0.000 0.286 2.164 2.251 12.135
04 - 202232****** IQ7+ [5] VCOP 0.000 0.288 2.190 2.270 12.205
05 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.988 2.057 11.157
06 - 202245****** IQ7+M [5] VCOP 0.000 0.285 2.175 2.295 12.344
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.280 2.001 2.017 10.947 0.000 kW
2.016 kWh
0.000 kW
10.078 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.281 2.019 2.122 11.317
09 - 202217****** IQ7+ [5] VCOP 0.000 0.279 2.001 2.065 11.144
10 - 202244****** IQ7+M [5] VCOP 0.000 0.280 2.028 2.133 11.416
11 - 202224****** IQ7+M [5] VCOP 0.000 0.280 2.029 2.138 11.429
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.269 2.146 2.347 12.918 0.000 kW
2.137 kWh
0.000 kW
8.550 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.271 2.105 2.256 12.584
14 - 202216****** IQ7+ [5] VCOP 0.000 0.273 2.164 2.331 12.901
15 - 202245****** IQ7+M [5] VCOP 0.000 0.269 2.135 2.285 12.659
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 54.51 V Current/Power 170.15 A (9.275 kW)
Remain Capacity/Energy 567.3 Ah (29.0 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 98.3 % State Of Health 96.2 %
Run Time 3m to full Report Date 2020-06-10 23:17
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 54.51 V Cell (MIN/MAX) 3.399 V / 3.414 V (0.015 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 189.1 Ah (9.7 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 98.3 % State Of Health 96.2 %
Temperature 24.0 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-10 23:17
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.408 V 3.399 V 3.407 V 3.401 V 3.410 V 3.404 V 3.402 V 3.411 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.408 V 3.400 V 3.409 V 3.404 V 3.412 V 3.403 V 3.413 V 3.414 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -