Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.500 kW
12/21/2025 15:37 (2034 days) Production Consumption NET Usage
Now 0.473 kW 0.973 kW 0.500 kW
Today 9.412 kWh (0.602 kW) 8.301 kWh (0.531 kW) -1.111 kWh (-0.071 kW)
  - This Week 9.412 kWh (14.449 kWh/day) 8.301 kWh (12.743 kWh/day) -1.111 kWh (-1.706 kWh/day)
  - This Month 184.318 kWh (8.925 kWh/day) 431.582 kWh (20.898 kWh/day) 247.264 kWh (11.973 kWh/day)
  - This Year 6.053 MWh (17.068 kWh/day) 7.348 MWh (20.719 kWh/day) 1.295 MWh (3.650 kWh/day)
Yesterday 12.220 kWh (0.509 kW) 17.015 kWh (0.709 kW) 4.795 kWh (0.200 kW)
Last 7 Days 54.155 kWh (7.736 kWh/day) 162.008 kWh (23.142 kWh/day) 107.853 kWh (15.406 kWh/day)
Last 30 Days 254.381 kWh (8.479 kWh/day) 620.587 kWh (20.686 kWh/day) 366.206 kWh (12.207 kWh/day)
Last One Year 6.114 MWh (16.749 kWh/day) 7.595 MWh (20.809 kWh/day) 1.482 MWh (4.059 kWh/day)
Lifetime Since PTO 35.504 MWh (17.449 kW/day) 39.301 MWh (19.315 kW/day) 3.796 MWh (1.866 kW/day)
Lifetime Since Install 35.538 MWh 39.881 MWh 4.343 MWh
Voltage/Current 251.0 V / 1.9 A 250.9 V / 3.9 A 251.0 V / 2.0 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/15/2020 23:44 (14.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.933 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.290 2.007 2.384 14.849 0.000 kW
1.915 kWh
0.000 kW
11.492 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.930 2.300 14.327
03 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.916 2.277 14.265
04 - 202232****** IQ7+ [5] VCOP 0.000 0.294 1.938 2.305 14.388
05 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.740 2.077 13.084
06 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.960 2.333 14.532
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 1.740 2.103 12.900 0.000 kW
1.783 kWh
0.000 kW
8.914 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.794 2.125 13.364
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.770 2.092 13.065
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.807 2.132 13.424
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.803 2.143 13.452
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.275 2.146 2.490 14.979 0.000 kW
2.132 kWh
0.000 kW
8.528 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.278 2.099 2.428 14.521
14 - 202216****** IQ7+ [5] VCOP 0.000 0.278 2.160 2.491 14.952
15 - 202245****** IQ7+M [5] VCOP 0.000 0.275 2.122 2.444 14.667
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.03 V Current/Power 175.03 A (9.808 kW)
Remain Capacity/Energy 577.2 Ah (29.6 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 100.0 % State Of Health 96.2 %
Run Time - to full Report Date 2020-06-15 23:34
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.03 V Cell (MIN/MAX) 3.496 V / 3.508 V (0.012 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 192.4 Ah (9.9 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 100.0 % State Of Health 96.2 %
Temperature 24.5 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-15 23:34
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.496 V 3.498 V 3.498 V 3.500 V 3.500 V 3.500 V 3.505 V 3.502 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.498 V 3.503 V 3.500 V 3.508 V 3.502 V 3.506 V 3.504 V 3.505 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -