Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.891 kW
04/07/2026 21:55 (2141 days) Production Consumption NET Usage
Now 0.317 kW -0.574 kW -0.891 kW
Today 34.951 kWh (1.594 kW) 10.204 kWh (0.465 kW) -24.747 kWh (-1.128 kW)
  - This Week 70.869 kWh (24.321 kWh/day) 34.905 kWh (11.979 kWh/day) -35.964 kWh (-12.342 kWh/day)
  - This Month 123.474 kWh (17.859 kWh/day) 95.964 kWh (13.880 kWh/day) -27.510 kWh (-3.979 kWh/day)
  - This Year 1.353 MWh (13.960 kWh/day) 1.661 MWh (17.142 kWh/day) 0.308 MWh (3.182 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 123.474 kWh (17.639 kWh/day) 97.019 kWh (13.860 kWh/day) -26.455 kWh (-3.779 kWh/day)
Last 30 Days (03/08/2026) 614.537 kWh (20.485 kWh/day) 443.425 kWh (14.781 kWh/day) -171.112 kWh (-5.704 kWh/day)
Last One Year 6.160 MWh (16.876 kWh/day) 7.828 MWh (21.447 kWh/day) 1.668 MWh (4.571 kWh/day)
Lifetime Since PTO 36.919 MWh (17.236 kW/day) 41.172 MWh (19.222 kW/day) 4.253 MWh (1.986 kW/day)
Lifetime Since Install 36.952 MWh 41.752 MWh 4.800 MWh
Voltage/Current 250.3 V / 1.3 A 250.3 V / -2.3 A 250.3 V / -3.6 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/02/2020 22:50 (10.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.649 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.059 1.075 7.383 0.000 kW
1.050 kWh
0.000 kW
6.303 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.299 1.046 1.059 7.308
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.057 1.073 7.323
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.048 1.059 7.363
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.052 1.025 7.260
06 - 202245****** IQ7+M [0] ---- 0.000 0.295 1.041 1.024 7.249
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 1.173 0.997 7.604 0.000 kW
1.171 kWh
0.000 kW
5.855 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.183 0.875 7.316
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.149 1.044 7.644
10 - 202244****** IQ7+M [0] ---- 0.000 0.298 1.175 1.050 7.707
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.175 1.034 7.677
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.220 0.622 0.991 5.622 0.000 kW
0.623 kWh
0.000 kW
2.491 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.220 0.612 0.985 5.591
14 - 202216****** IQ7+ [0] ---- 0.000 0.218 0.635 0.990 5.714
15 - 202245****** IQ7+M [0] ---- 0.000 0.216 0.622 0.971 5.648
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.03 V Current/Power 175.06 A (9.808 kW)
Remain Capacity/Energy 566.4 Ah (29.0 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 95.8 % State Of Health 98.5 %
Run Time 8m to full Report Date 2020-10-02 23:54
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.03 V Cell (MIN/MAX) 3.494 V / 3.504 V (0.010 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 188.8 Ah (9.7 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 95.8 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-10-02 23:54
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.494 V 3.499 V 3.496 V 3.501 V 3.502 V 3.501 V 3.504 V 3.503 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.501 V 3.502 V 3.501 V 3.499 V 3.503 V 3.504 V 3.503 V 3.504 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -