Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.157 kW
12/21/2025 14:44 (2034 days) Production Consumption NET Usage
Now 0.474 kW 0.317 kW -0.157 kW
Today 9.115 kWh (0.618 kW) 7.366 kWh (0.499 kW) -1.749 kWh (-0.119 kW)
  - This Week 9.115 kWh (14.829 kWh/day) 7.366 kWh (11.984 kWh/day) -1.749 kWh (-2.845 kWh/day)
  - This Month 184.021 kWh (8.927 kWh/day) 430.647 kWh (20.890 kWh/day) 246.626 kWh (11.964 kWh/day)
  - This Year 6.053 MWh (17.069 kWh/day) 7.347 MWh (20.718 kWh/day) 1.294 MWh (3.649 kWh/day)
Yesterday 12.220 kWh (0.509 kW) 17.015 kWh (0.709 kW) 4.795 kWh (0.200 kW)
Last 7 Days 54.155 kWh (7.736 kWh/day) 162.008 kWh (23.142 kWh/day) 107.853 kWh (15.406 kWh/day)
Last 30 Days 254.381 kWh (8.479 kWh/day) 620.587 kWh (20.686 kWh/day) 366.206 kWh (12.207 kWh/day)
Last One Year 6.114 MWh (16.749 kWh/day) 7.595 MWh (20.809 kWh/day) 1.482 MWh (4.059 kWh/day)
Lifetime Since PTO 35.504 MWh (17.450 kW/day) 39.300 MWh (19.315 kW/day) 3.796 MWh (1.866 kW/day)
Lifetime Since Install 35.538 MWh 39.880 MWh 4.342 MWh
Voltage/Current 250.8 V / 1.9 A 250.8 V / 1.3 A 250.8 V / -0.6 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/22/2020 23:31 (14.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.453 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.002 1.845 13.391 0.000 kW
1.908 kWh
0.000 kW
11.449 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.927 1.789 12.977
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.909 1.770 12.920
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.929 1.789 13.021
05 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.721 1.584 11.834
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.962 1.821 13.146
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.714 1.563 11.762 0.000 kW
1.794 kWh
0.000 kW
8.971 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.812 1.654 12.095
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.774 1.607 11.955
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.833 1.675 12.180
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.839 1.684 12.185
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.291 2.037 1.914 13.843 0.000 kW
2.008 kWh
0.000 kW
8.033 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.291 1.958 1.855 13.567
14 - 202216****** IQ7+ [5] VCOP 0.000 0.292 2.040 1.917 13.921
15 - 202245****** IQ7+M [5] VCOP 0.000 0.287 1.998 1.886 13.694
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.02 V Current/Power 175.03 A (9.805 kW)
Remain Capacity/Energy 517.5 Ah (26.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 89.7 % State Of Health 96.2 %
Run Time 20m to full Report Date 2020-06-22 23:48
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.02 V Cell (MIN/MAX) 3.495 V / 3.507 V (0.012 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 172.5 Ah (8.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 89.7 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-22 23:48
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.499 V 3.495 V 3.503 V 3.503 V 3.501 V 3.501 V 3.503 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.498 V 3.497 V 3.500 V 3.501 V 3.500 V 3.504 V 3.504 V 3.507 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -